11
Monitor Menu
CONTROLLER DIAGNOSTIC TOOL (CDT)
REVERSE INPUT
With the Forward/Reverse switch in the NEUTRAL or FORWARD position, the handset should indicate that the
reverse input is off. When the Forward/Reverse switch is placed in the REVERSE position, the handset should
indicate that the reverse input is on.
MODE SWITCH
Indicates what position the Mode Switch is in (On or Off).
WK AWAY RELAY
Displays the state of the Walk Away Relay (On or Off). If the speed controller detects that the throttle is at 0% and
the vehicle is moving, the relay will activate, reversing the direction of the field current until no motion of the vehicle
is detected.
MAIN CONT
Displays the state of the solenoid (main contactor). When the contactor is activated, the handset indicates that the
solenoid is on. When the contactor is not activated, the handset indicates that the solenoid is off.
PASSWORD TRIES (OEM ACCESS LEVEL ONLY)
A password is required to activate Mode 2.The speed controller will log unsuccessful and unauthorized attempts to
activate Mode 2. If repeated attempts are unsuccessful, the speed controller will permanently lock out access to Mode
2. In the event that Mode 2 is locked out, the controller must be removed and shipped to Club Car before Mode 2
can be activated.
NOTE: The lower portion of the monitor menu contains the fault counter information. Each fault is listed in the left
hand column and the number of occurances will be listed in the right hand column.
CIR BRKR OPEN #
Displays the number of times the CIR BRKR OPEN fault has been detected. See Fault Descriptions on page 11-20.
THRTL FAULT #
Displays the number of times the THRTL fault has been detected. See Fault Descriptions on page 11-20.
UNDERVOLTAGE #
Displays the number of times the UNDERVOLTAGE fault has been detected. See Fault Descriptions on page 11-20.
OVERVOLTAGE #
Displays the number of times the OVERVOLTAGE fault has been detected. See Fault Descriptions on page 11-20.
TEMP CUTBACK #
Displays the number of times the TEMP CUTBACK fault has been detected. See Fault Descriptions on page 11-20.
HPD #
Displays the number of times the HPD fault has been detected. See Fault Descriptions on page 11-20.
MAIN WELDED #
Displays the number of times the MAIN WELDED fault has been detected. See Fault Descriptions on page 11-20.
Page 11-12
2016 Carryall 500 and 700 Maintenance and Service Manual