11
Parameters
23
24
25
26
27
28
29
30
Control Mode
The control mode option is used to configure the controller for different modes of speed control operation. Four
modes are avaiable:
• 0 = Standard: Uses maximum speeds defined in the parameters.
• 1 = LIN (Local Interconnect bus) (i.e. Guardian or Visage): Uses maximum speeds assigned to a particular location
or area as defined by the fleet operator; however, these defined speeds can not override maximums set in the
parameters.
• 2 = ES-Protocol (UpLink): Uses maximum speeds assigned to a particular location or area as defined by the fleet
operator; however, these defined speeds can not override previously set values from other control mode options. To
avoid this, after changing the control mode to 2, cycle power to the controller by placing the Tow/Run Switch in the
TOW position for 30 seconds. Then return it to RUN.
• 3 = Deterrent Demo Mode: Uses maximum speeds defined by the deterrent demo setting to demonstrate the
automatic speed control features of Guardian and UpLink. See Deterrent Demo on page 11-8.
Anti-Tamper
The anti-tamper setting defines maximum speed if the Anti-Tamper fault is triggered (e.g. controller is disconnected
from the Guardian or Visage system). These speeds can only be activated if the Control Mode option is set to 1
(Guardian/Visage) and are intended to be a deterrent. Factory default setting is 1.
• 0 = OFF; uses controller configured speed even if the Anti-Tamper fault is triggered
• 1 = 2 mph
• 2 = 0 mph
• 3 = 7 mph
Deterrent Demo
The deterrent demo setting defines maximum speed of Control Mode 3.
• 0 = Controller configured speed
• 1 = 10 mph
• 2 = 7 mph
• 3 = 2 mph
WalkAway Deterrent
The walkaway deterrent menu item allows the user to turn this function ON or OFF. Walkaway deterrent is triggered by
the High Speed WalkAway fault. With it ON, the reverse buzzer will sound immediately upon the key switch being turned
OFF at speeds above 2 mph. With it OFF, the buzzer will cycle on and off at a higher frequency (7.5 Hz vs. 2.5 Hz).
Battery Type
The battery type menu item is intended to be used with Guardian/Visage so that the type of battery could be determined
and displayed when remotely monitoring vehicles.
Page 11-8
2016 Carryall 500 and 700 Maintenance and Service Manual
5.7 mph (9.2 km/h)
9.7 mph (15.6 km/h)
5.6 mph (9.0 km/h)
9.6 mph (15.4 km/h)
5.5 mph (8.9 km/h)
9.5 mph (15.3 km/h)
5.4 mph (8.7 km/h)
9.4 mph (15.1 km/h)
5.3 mph (8.5 km/h)
9.3 mph (15.0 km/h)
5.2 mph (8.4 km/h)
9.2 mph (14.8 km/h)
5.1 mph (8.2 km/h)
9.1 mph (14.6 km/h)
5.0 mph (8.0 km/h)
9.0 mph (14.5 km/h)
CONTROLLER DIAGNOSTIC TOOL (CDT)
12.7 mph (20.4 km/h)
14.7 mph (23.7 km/h)
12.6 mph (20.3 km/h)
14.6 mph (23.5 km/h)
12.5 mph (20.1 km/h)
14.5 mph (23.3 km/h)
12.4 mph (20.0 km/h)
14.4 mph (23.2 km/h)
12.3 mph (19.8 km/h)
14.3 mph (23.0 km/h)
12.2 mph (19.6 km/h)
14.2 mph (22.9 km/h)
12.1 mph (19.5 km/h)
14.1 mph (22.7 km/h)
12.0 mph (19.3 km/h)
14.0 mph (22.5 km/h)