Error Responses; Sis Command And Response Format - Extron electronics PowerCage 411 Series User Manual

Modular power enclosure and fiber optic extenders
Table of Contents

Advertisement

Password:
The PowerCage issues the password prompt immediately after the copyright message
when the controlling system is connected using TCP/IP or an SSH client and the
PowerCage is password protected. This message means that the PowerCage requires an
administrator or user level password before it will perform the commands entered via this
link. The PowerCage repeats the password message response until a valid password is
entered.
NOTE: The factory configured passwords for all accounts on this device have been set
to the device serial number. In the event of a complete system reset, the passwords
convert to the default, which is extron for the Admin and User (see
Panel

Error Responses

When the PowerCage 411 enclosure receives an SIS command and determines that it is
valid, it performs the command and sends the corresponding response to the host device.
If the command is determined invalid or contains invalid parameters, the PowerCage
enclosure returns an error response to the host. The error response codes are:
— Invalid command
E10
E11
— Invalid preset number
— Invalid parameter
E13
E14
— Invalid for this configuration
— Invalid command for signal type
E17
E18
— System/command timed out

SIS Command and Response Format

Commands and responses to and from the individual boards are routed through the
PowerCage 411 enclosure. The SIS commands and responses for the enclosure appear
in the SIS tables (see
page 38).
NOTE: An SIS command to a specific slot device that begins with E MUST end with
the pipe ( | ), not the
To send commands to boards in an enclosure, use the following format:
X)
command
{
:
X)
= The slot number (1-4)
NOTE: To enter multiple slot numbers, separate each slot number with a comma (
SIS responses return in the following format:
X)
response
{
}
X)
= The slot number (1-4)
NOTE: If multiple slots are defined in the command, responses from each slot are
separated onto different lines.
]
on page 58 to change a password).
Command and Response Tables for SIS Commands
}
. For example: {1:
}
}
PowerCage 411 Series • SIS Configuration and Control
— Invalid room number
E21
E22
— Busy
— Privilege violation
E24
E25
— Device not present
— Maximum number of connections exceeded
E26
E28
— Bad filename or File not found
E
| }} .
E1HDCP
Passwords
starting on
).
,
34