Exit Menu; Error Messages - Extron electronics PowerCage 411 Series User Manual

Modular power enclosure and fiber optic extenders
Table of Contents

Advertisement

Exit Menu

The EXIT MENU returns to the slot menu or to the default cycle.
Exit Menu
EXIT MENU?
PRESS NEXT
NEXT
DEFAULT
CYCLE
Figure 20.

Error Messages

When either a fan or power supply fail, the LCD menu displays an error message to alert
the user. Users can ignore the message and continue with normal operations by pressing
the MENU and NEXT buttons to cycle through the LCD menu. However, the failed message
continues to re-appear in the default cycle until the fault has been repaired.
When one of the internal fans fails or the RPM goes
below 100 RPM, one of the four messages on the right
displays.
When one of the internal power supplies fails or the
output voltage goes below 10% of 12 V, one of the
two messages on the right displays.
MENU
SLOT MENU
EXIT MENU Flowchart
FAILED:
FAN 1
FAILED:
FAN 3
FAILED:
PWR SUPPLY 1
PWR SUPPLY 2
PowerCage 411 Series • Operation
FAILED:
FAN 2
FAILED:
FAN 4
FAILED:
27