Extron electronics PowerCage 411 Series User Manual page 29

Modular power enclosure and fiber optic extenders
Table of Contents

Advertisement

Mode
Activation
1
Hold in the recessed Reset button
for approximately 30 seconds while
applying power to the unit.
NOTE:
Do not operate with the default firmware loaded by a mode 1 reset. Use it only to load the most
current firmware to the device.
*4
Hold in the Reset button for about
6 seconds until the Reset LED blinks
twice. Then release and press the
Reset button again within 1 second.
*5
Hold in the Reset button for about
9 seconds until the Reset LED blinks
three times (once at 3 seconds,
again at 6 seconds, again at
9 seconds). Then, release and
press the Reset button again within
1 second.
NOTES:
*For modes 4 and 5, nothing happens if the momentary press does not occur within 1 second.
The factory configured passwords for all accounts on this enclosure have been set to the enclosure
serial number. In the event of a complete system reset, the passwords convert to the default, which
is extron (see
Passwords Panel
PowerCage 411 Reset Mode Summary
The device reverts to the factory default
firmware for a single power cycle. All user
files and settings (audio adjustments,
video settings, IP settings, and the like)
are maintained.
Sets the following back to factory default:
Port mapping
IP address (192.168.254.254)
Subnet (255.255.255.0)
Gateway address (0.0.0.0)
Turns DHCP off
The Reset LED flashes four times in
quick succession during reset.
A complete reset of the enclosure to
factory defaults (except the firmware).
Does everything mode 4 does.
Resets all user modifiable
configurations to default values
including IP settings and real time
adjustments.
Deletes all user loaded files.
The Reset LED flashes four times in
quick succession during the reset.
on page 58 to change a password).
Result
Use to revert back to
factory default firmware
for a single power cycle if
incompatibility issues arise.
Use to reset all IP settings
back to factory defaults.
Equivalent to SIS
command 1ZQQQ (see
Resets
Use to restart with the
default configuration.
Equivalent to SIS
command ZQQQ (see
Resets).
PowerCage 411 Series • Operation
Purpose/Notes
on page 38).
21