1.3 Technical Data BlueBox T4 Basic

Computer:
Display black and white:
Display coloured:
Storage media:
Mechanical data:
Power supply:
Interfaces:
Modem (optional):
Ambient conditions:
To ensure equipment protection and the proper functioning of the device, the above conditions are strictly to be
adhered to!
The connected modules receive their power from the BlueBox. Some modules have a constricted input range, so there is a
input voltage tolerance of ± 10%.
GO Systemelektronik GmbH
PC 104, 200 MHz to 500 MHz
Operation system: Embedded Linux®
Main memory 256 MB
Touchpanel 240 x 128 pixel
Touchpanel 480 x 272 pixel
Industrial CompactFlash card 256 MB; 512 Mb; 2 GB
Housing dimensions:
Weight:
IP code (housing):
Die-cast aluminium housing, powder coated
Colour:
Nominal voltage:
Nominal power:
additionally max. 1.85 A via the output to the modules
1 x CAN
1 x USB (not TS and TC)
1 x Ethernet 10 or 100 Mbit/s
1 x RS-232 or RS-485 (half-duplex)
2 x current output 4 mA – 20 mA
Modem HSPA or Modem ISDN/analogue
Ambient temperature: Storage:
Relative humidity:
Faluner Weg 1
24109 Kiel
www.go-sys.de
280 mm x 170 mm x 90 mm (W x L x H)
approx. 2.5 kg
IP65
RAL 5010
24 V DC (18 V – 28 V)
10 W
-10 °C to +50 °C
Operation:
-20 °C to +45 °C
avoid direct sunlight
≤ 90 % (annual average)
Germany
Tel.: +49 431 58080-0
info@go-sys.de
Article-No. 486 0003
Page 10 / 99
Fax: -58080-11

Advertisement