GO Systemelektronik BlueBox T4 Manual
Hide thumbs Also See for BlueBox T4:
Table of Contents

Advertisement

Quick Links

Manual
BlueBox T4
Version of this manual: 2.21 en
www.go-sys.de

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BlueBox T4 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for GO Systemelektronik BlueBox T4

  • Page 1 Manual BlueBox T4 Version of this manual: 2.21 en www.go-sys.de...
  • Page 2 GO Systemelektronik GmbH. Changes GO Systemelektronik GmbH retains the right to modify the contents of the manual without prior notice. Liability exclusion GO Systemelektronik GmbH takes no responsibility for correct system operation under all possible operating conditions.
  • Page 3 B l u e B o x blank page Page 3 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0 Fax: -58080-11 www.go-sys.de info@go-sys.de...
  • Page 4: Table Of Contents

    3.3 Connections BlueBox T4 Basic................................18 3.3.1 Connection Options BlueBox T4 Basic............................18 3.3.2 Connector Pin Assignment at the BlueBox T4 Basic ........................19 3.4 Connecting of the Power Supply................................20 3.5 LAN Connection..................................... 21 3.6 Notes on the IP Protection Code ..........................
  • Page 5 Appendix G – Older Power Supply 150 W Switch 110/230 VAC ........................89 Appendix H – Mainboard Connections BlueBox T4 ............................91 Appendix I – Mainboard Connections BlueBox T4 Basic ..........................93 Appendix J – Status Messages ..................................95 Appendix K –...
  • Page 6: Overview

    B l u e B o x 1 Overview The BlueBox is available in four versions, as BlueBox T4, BlueBox T4 Basic, BlueBox TS and BlueBox TC. This manual describes the versions T4 and T4 Basic, different properties of the other versions are de- scribed in separate manuals.
  • Page 7: Meaning Of The Safety Instructions

    It is possible to connect multiple sensors/actuators to one module. A star circuit can only be used with a repeater (see 5 Active CAN Repeater). optional Page 7 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0 Fax: -58080-11 www.go-sys.de...
  • Page 8 B l u e B o x System setup: Network setup: Page 8 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0 Fax: -58080-11 www.go-sys.de info@go-sys.de...
  • Page 9: Technical Data Bluebox T4

    B l u e B o x 1.3 Technical Data BlueBox T4 Computer: PC 104, 800 MHz Operation system: Embedded Linux® Main memory 512 MB Article-No. 486 0004 Display: Touch panel 95 mm x 54 mm; 480 x 272 pixel; colour Storage media: Industrial NANDrive™...
  • Page 10: Technical Data Bluebox T4 Basic

    B l u e B o x 1.4 Technical Data BlueBox T4 Basic Computer: PC 104, 800 MHz Operation system: Embedded Linux® Main memory 512 MB Article-No. 486 0003 Display colour: Touch panel 95 mm x 54 mm; 480 x 272 pixel Display monochrome: Touch panel 95 mm x 60 mm;...
  • Page 11: Notes On The Current Outputs

    The connections are located at the bottom of the BlueBox, see 3.2.2 Connector Pin Assignment at the BlueBox T4 or 3.3.2 Connector Pin Assignment at the BlueBox T4 Basic. The measurement values of an assigned sensor control a current output. The assignment of a sensor to a current output is done with the program AMS (AMS is part of the BlueBox PC Software).
  • Page 12: Notes On The Storage Space Management Of The Nandrive

    So the deletion of old sensor data starts here after approx. 5½ months It is recommended to choose the measurement interval as large as possible. ∗ and possibly GPS data contained therein Page 12 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0 Fax: -58080-11 www.go-sys.de...
  • Page 13: Notes On Operation

    • was exposed to improper transport conditions. In cases of doubt give notice to GO Systemelektronik GmbH. If necessary send the device to GO Systemelek- tronik for reparation respectively maintenance. Page 13 / 96...
  • Page 14: Installation

    A great advantage of the BlueBox is their design flexibility. Therefore construction of installation will vary by application. A description of the structure and assembly of the BlueBox can only serve as an example. ∗ HSPA/LTE, ISDN, analogue Page 14 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0 Fax: -58080-11 www.go-sys.de...
  • Page 15: Connections Bluebox T4

    B l u e B o x 3.2 Connections BlueBox T4 3.2.1 Connection Options BlueBox T4 The BlueBox has the following connection options: 1. Power supply (24 VDC) via a 4-pin M12 panel plug (male) 2. CAN-bus connection via a 5-pin M12 panel socket (female) Connection of BlueBox sensor-/actuator modules via a 4-wire CAN-bus connection cable 3.
  • Page 16: Connector Pin Assignment At The Bluebox T4

    B l u e B o x 3.2.2 Connector Pin Assignment at the BlueBox T4 Power supply 24 VDC panel plug (M12, male) +24 VDC GND 24 V CAN-bus panel socket (M12, female) CAN-H CAN-L +24 VDC GND 24 V...
  • Page 17 (M8, female) +24 VDC I-Return Pulse input panel plug (M8, male) 24 V Pulse input 1 2 Page 17 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0 Fax: -58080-11 www.go-sys.de info@go-sys.de...
  • Page 18: Connections Bluebox T4 Basic

    B l u e B o x 3.3 Connections BlueBox T4 Basic 3.3.1 Connection Options BlueBox T4 Basic The BlueBox has the following connection options: Ground connection Power supply (24 VDC) via a 4-pin M12 panel plug (male) CAN-bus connection via a 5-pin M12 panel socket (female)
  • Page 19: Connector Pin Assignment At The Bluebox T4 Basic

    B l u e B o x 3.3.2 Connector Pin Assignment at the BlueBox T4 Basic Power supply 24 VDC panel plug (M12, male) +24 VDC GND 24 V CAN-bus panel socket (M12, female) CAN-H CAN-L +24 VDC GND 24 V...
  • Page 20: Connecting Of The Power Supply

    Insert the at 24 VDC power supply cable socket into the in the corresponding panel plug of the BlueBox. ∗ siehe Anhang G – Älteres Netzteil 150 W umschalten 110/230 VAC Page 20 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0...
  • Page 21: Lan Connection

    USB- and LAN-plugs with protection code IP65 or higher The plugs and protection caps delivered by GO Systemelektronik have protection code IP65. USB- and LAN plugs with protection code IP65 can be ordered from GO Systemelektronik. ∗ except of course the ground connection...
  • Page 22: Can-Bus Termination At The Bluebox

    If the BlueBox is factory presetted to RS-485, then the interface is terminated by the factory. ∗ see Appendix F – Opening of a BlueBox Housing Page 22 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0 Fax: -58080-11 www.go-sys.de...
  • Page 23: Connection Of Modules

    M12 Y-splitter is plugged in and is fixed by turning The connection to the BlueBox is an M12 panel the union nut. socket (see 3.2 Connections BlueBox T4 or 3.3 Con- M12 panel socket nections BlueBox T4 Basic). The first and last element must be terminated in a bus structure (see 4.3 Termination of the CAN-bus).
  • Page 24: Can-Bus Cable To M12 Cable Plug

    Only the num- bering of the contacts is valid Termination ON Module connection with spring clips (final module) Page 24 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0 Fax: -58080-11 www.go-sys.de...
  • Page 25: Termination Of The Can-Bus

    (WH) +24 VDC Termination at an active CAN repeater brown (BN) GND 24 V see 5 Active CAN Repeater Page 25 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0 Fax: -58080-11 www.go-sys.de...
  • Page 26: Checking The Termination

    Make sure that all elements of the CAN-bus chain are voltage free. The measurement procedure is described below: Correct termination Page 26 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0 Fax: -58080-11 www.go-sys.de...
  • Page 27: Active Can Repeater

    5 Active CAN Repeater Article-No. 486 R000 The active CAN repeater from GO Systemelektronik is a module for expanding the CAN bus structure. The active CAN repeater has eight galvanically isolated bus lines. Each of these bus lines can connect up to five elements on a length of up to 1000 m.
  • Page 28: The Configuration Data Sheet

    B l u e B o x 6 The Configuration Data Sheet The configuration data sheet contains the necessary settings to run the BlueBox. Example BlueBox T4: 1. BlueBox T4: Serial Number A1234 BlueBox Password (PIN) xxxxx Storage Device SST-512...
  • Page 29 BlueBox SQL Software. 14111 / or with activated encryption 14110 IP address of the GO webserver (default address) changeable only at the default address Page 29 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0 Fax: -58080-11 www.go-sys.de...
  • Page 30: Switching On The Bluebox And Password Input

    (see Appendix A – Adjustment of the Touch Display). The practical benefit increases with the size of the system The setup of virtual sensors is done with the AMS software, see manual BlueBox PC Software. Page 30 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0...
  • Page 31 < Verifies the password and switches to the System menu. <– If the password is incorrect, you receive an error message. Page 31 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0 Fax: -58080-11 www.go-sys.de...
  • Page 32: The Menu Operation

    8 The Menu Operation The BlueBox T4 has a colour display. The BlueBox T4 Basic has a colour display in the newer versions, versions with a monochrome display are no longer available. The operation on the monochrome display is almost identical to the operation on the colour display and dif- fers most in the measurement value display (see 8.1 Parameter Display and following).
  • Page 33: Parameter Display 1-Way

    M enu ∗ The sequence is that of the ASCII numeric value, i. e.: Special characters  numbers  capital letters  lower case letters Page 33 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0 Fax: -58080-11 www.go-sys.de...
  • Page 34: Parameter Display 6-Way

    M enu ∗ The sequence is that of the ASCII numeric value, i. e.: Special characters  numbers  capital letters  lower case letters Page 34 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0 Fax: -58080-11 www.go-sys.de...
  • Page 35: Parameter Display 8-Way (Tiles)

    M enu ∗ The sequence is that of the ASCII numeric value, i. e.: Special characters  numbers  capital letters  lower case letters Page 35 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0 Fax: -58080-11 www.go-sys.de...
  • Page 36: Main Menu

    Switches to the menu of the user defined variables, see 8.2.5 User Variables. User Switches to the Help menu, see 8.2.6 Help menu. Help Switches back to the parameter display. <– Page 36 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0 Fax: -58080-11 www.go-sys.de...
  • Page 37: System Menu

    Switches to the Display menu, see 8.2.1.6 Display. Displ ay Switches to the Language menu, see 8.2.1.7 Language Settings. Language Switches back to the Main menu. <– Page 37 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0 Fax: -58080-11 www.go-sys.de...
  • Page 38: Network Menu

    DNS ser ver Switches to the Info menu, see 8.2.1.1.7 Info Network. Over view Switches back to the System menu. <– Page 38 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0 Fax: -58080-11 www.go-sys.de...
  • Page 39: Ip-Address Input

    IP address. DHCP The button is also a status indicator. Saves the entry and switches back to the Network menu. Page 39 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0 Fax: -58080-11 www.go-sys.de...
  • Page 40: Ip-Netmask Input

    Password xxxxx see 6 The Configuration Data Sheet Saves the entry and switches back to the Network menu. <– Page 40 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0 Fax: -58080-11 www.go-sys.de...
  • Page 41: Gateway Ip-Address Input (Default Gateway)

    Even works with on a block. After confirmation, sets the setting to "0.0.0.0.0". Saves the entry and switches back to the Network menu. Page 41 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0 Fax: -58080-11 www.go-sys.de...
  • Page 42: Time Server Input

    & < –> GO Systemelektronik provides a time server under the URL "ntp.go-sys" (IP address 212.51.30.18) – the only requirement here is that the BlueBox has Internet access. Saves the input and switches back to the Network menu. Deletes the last entered character.
  • Page 43: Internet Settings

    Switches to the menu of the DynDNS settings of the Internet connection. Only by a D ynDNS settings connection via GPRS/UMTS modem. For service tasks GO Systemelektronik can access from the outside to the Ser vice enabled BlueBox. Service enabled: access to the operating system functions of BlueBox...
  • Page 44: Udp Settings

    Password Only visible at <Encryption on>. Switches back to the menu Internet settings. <– ∗ UDP = User Datagram Protocol Page 44 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0 Fax: -58080-11 www.go-sys.de...
  • Page 45: Setting Ip Address (Udp)

    Enter the IP address using the numeric buttons in the marked block. If an access to the BlueGate server has been ordered from GO Systemelektronik, the IP address is set to the standard address 212.51.30.18 on delivery of the BlueBox.
  • Page 46: Setting Password Of The Encryption

    Saves the input and switches back to the UDP settings. Deletes the last entered character. Switches back to the UDP settings without saving the input. Page 46 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0 Fax: -58080-11 www.go-sys.de...
  • Page 47: Gateway Settings (Internet)

    If the BlueBox shall communicate bidirectional with a computer in the Internet, enter here the IP address of your BlueBox gateway and the associated password. IP address and password you get from GO Systemelektronik (see 6 The Configuration Data Sheet). Gateway settings...
  • Page 48: Input Gateway Settings (Internet)

    –> Saves the input and switches back to the Gateway Settings (Internet) menu. Deletes the last entered character. Deletes the last entered character. Page 48 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0 Fax: -58080-11 www.go-sys.de...
  • Page 49: Dyndns Settings

    Precondition is : 1. Your GPRS / UMTS Internet connection has a public IP address. 2. The access is not blocked by the provider. Page 49 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0 Fax: -58080-11 www.go-sys.de...
  • Page 50: Dyndns Settings Input

    Saves the input and switches back to the DynDNS Settings menu. Deletes the last entered character. Switches back to the DynDNS Settings without saving the input. Page 50 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0 Fax: -58080-11 www.go-sys.de...
  • Page 51: Dns Server Input

    Even works with on a block. After confirmation, sets the setting to "0.0.0.0.0". Saves the entry and switches back to the Network menu. Page 51 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0 Fax: -58080-11 www.go-sys.de...
  • Page 52: Info Network

    Standard time The button is also a status indicator. Daylig ht saving time Switches back to the System menu. <– Page 52 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0 Fax: -58080-11 www.go-sys.de...
  • Page 53: Date Input

    Selection -1 Selection +1 Switches back to the Time menu. <– First set the time zone before you set the time! Page 53 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0 Fax: -58080-11 www.go-sys.de...
  • Page 54: Time Drift Input

    Switches back to the Time menu. <– Please note that the setting described here only has impact on the displayed time zone and not on the data-bound time! Page 54 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0 Fax: -58080-11 www.go-sys.de...
  • Page 55: Shutdown

    You can switch off the BlueBox by disconnecting the power supply. If the BlueBox is not disconnected from the power supply after shutdown, it will automatically restart after 10 minutes. Page 55 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0...
  • Page 56: Modem Menu / Modem Settings

    (see: 8.2.1.4.3 Modem Type Settings). Switches to the Info menu of the modem settings. Over view Switches back to the System menu. <– Page 56 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0 Fax: -58080-11 www.go-sys.de...
  • Page 57: Modem Port Setup

    < Saves the input and switches back to the Modem menu. Switches back to the Modem menu without saving the input. <– Page 57 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0 Fax: -58080-11 www.go-sys.de...
  • Page 58: Mode Type Settings

    GPRS/UM TS GPRS/UM TS Saves the input and switches back to the Modem menu. <– ∗ optional extra equipment Page 58 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0 Fax: -58080-11 www.go-sys.de info@go-sys.de...
  • Page 59: Umts Settings

    Please note that the connected BlueBoxes must use the IP address of the routing BlueBox as the address of the default gateway (see 8.2.1.1.3 Gateway IP-Address Input (Default Gateway)). Page 59 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0...
  • Page 60: Umts Settings Input

    Saves the input and switches back to the UMTS Settings. Deletes the last entered character. Switches back to the UMTS Settings without saving the input. Page 60 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0 Fax: -58080-11 www.go-sys.de...
  • Page 61: Modem Info (Umts)

    Switches to the information menu of the GPS connection, here the relevant GPS data are Over view listed. Switches back to the System menu. <– Page 61 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0 Fax: -58080-11 www.go-sys.de...
  • Page 62: Gps Port Setup

    GPS module at serial interface via CAN-bus CAN6 Interface: CAN-bus serial 6 CAN6 Switches back to the GPS menu. <– Page 62 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0 Fax: -58080-11 www.go-sys.de...
  • Page 63: Display

    <– Appears only at a BlueBox with a colour display. The status of an actuators can also be understood as a measurement value. Page 63 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0 Fax: -58080-11 www.go-sys.de...
  • Page 64: Language Settings

    Polski Selection menu language Turkish, the button is also a status indicator. Türkçe Switches back to the System menu. <– Page 64 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0 Fax: -58080-11 www.go-sys.de...
  • Page 65: Sensor List

    <– ∗ The sequence is that of the ASCII numeric value, i. e.: Special characters  numbers  capital letters  lower case letters Page 65 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0 Fax: -58080-11 www.go-sys.de...
  • Page 66: Sensor Menus

    Lower limit Upper limit of the measuring range Upper limit ∗ The program AMS is part of the BlueBox PC Software. Page 66 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0 Fax: -58080-11 www.go-sys.de...
  • Page 67: Calibration

    Single- point calib ration y0=fix Two-point calib ration <– GO Systemelektronik recommends using the factory default settings Calibration mode one point calibration with a calibration line One point calib ration y0=0 through the zero point. The button is also a status indicator.
  • Page 68: Diagram Display (Sensor Values)

    Pressing the display switches back Pressing the display switches back to the sensor menu. to the sensor menu. Page 68 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0 Fax: -58080-11 www.go-sys.de...
  • Page 69: Sensor Info

    Parameter Name of the parameter Unit Unit of the parameter Last update Time and date of the last measurement Page 69 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0 Fax: -58080-11 www.go-sys.de info@go-sys.de...
  • Page 70: Interval And Average

    The measurement interval is calculated in advance from the set interval time, the number of individual measurements and the properties of the sensor. This results in a low time drift of the recording times of the measurement values. Page 70 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0...
  • Page 71: Actuator List

    <– ∗ The sequence is that of the ASCII numeric value, i. e.: Special characters  numbers  capital letters  lower case letters Page 71 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0 Fax: -58080-11 www.go-sys.de...
  • Page 72: Actuator Menu

    Switches the relay on, the button is also a status indicator. Switches the relay off, the button is also a status indicator. Switches back to the Actuator menu. <– Page 72 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0 Fax: -58080-11 www.go-sys.de...
  • Page 73: Diagram Display (Actuator)

    – default value for relays Unit unallocated Last update Time of the last function request; the function request takes place after each control interval. Page 73 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0 Fax: -58080-11 www.go-sys.de...
  • Page 74: Service Mode (Maintenance)

    Time+ Switches back to the Main menu. <– Once the maintenance time has elapsed, the display switches back to the main menu. Page 74 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0 Fax: -58080-11 www.go-sys.de...
  • Page 75: User Variables

    Switches back to the menu of the user variable without saving the entry <– ∗ see Manual BlueBox PC Software there 5.5.2 Variables there Variable types there At BlueBox adjustable permanently stored variables Page 75 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0 Fax: -58080-11 www.go-sys.de...
  • Page 76: Help Menu

    Serial number and Firmware version and Storage Firmware Version of the BlueBox  Display whether an uninterruptible power supply (UPS) is connected.  Switches back to the Help menu. <– Page 76 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0 Fax: -58080-11 www.go-sys.de...
  • Page 77: Current Output

    Switches back to Sensor list. <– The program AMS is part of the BlueBox PC Software. Except in special cases, calibration is performed with the AMS program. Page 77 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0 Fax: -58080-11 www.go-sys.de...
  • Page 78 & – < –> < –> < –> The program AMS is part of the BlueBox PC Software. Page 78 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0 Fax: -58080-11 www.go-sys.de info@go-sys.de...
  • Page 79: Appendix A - Adjustment Of The Touch Display

    A blinking dot appears at bottom right. touch this small dot - > Press the blinking dot bottom right. The adjustment is finished. Page 79 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0 Fax: -58080-11 www.go-sys.de...
  • Page 80: Appendix B - Calibrating Of A Ph Sensor

    Strictly spoken it is sufficient if the entry in the parameter field contains "pHGlas". For better visibility, "pHGlas" should be at the beginning. see 1.2 pH Sensor Calibration Reset to Default Page 80 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0...
  • Page 81 If during the calibration procedure the permissible range of values has been exceeded, this is displayed with inf or -inf. If undefined values were entered during the calibration procedure, this is displayed with nan. ∗ Buffer solution for calibration of pH sensors from GO Systemelektronik Page 81 / 96 GO Systemelektronik GmbH...
  • Page 82 Switches back to the Calibration menu pH sensor without saving the entry. Cancel Saves the entry and switches back to the Calibration menu pH sensor Page 82 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0 Fax: -58080-11 www.go-sys.de...
  • Page 83 Switches back to the Calibration menu pH sensor without saving the entry. Cancel Saves the entry and switches back to the Calibration menu pH sensor Page 83 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0 Fax: -58080-11 www.go-sys.de...
  • Page 84: Appendix C - Calibration Of A Galvanic Oxygen Sensor

    The temperature adjustment can be accelerated by immersing the sensor in water, which has approximately the temperature of the ambient air, before performing the saturation calibration. Moreover, abrupt temperature changes (e.g., by direct exposure to the sun) must be avoided. Page 84 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0...
  • Page 85 [NO] ∗ If the offset calibration menu appears and the sensor should produce values > 3 mV, the sensor may be defective. Page 85 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0 Fax: -58080-11 www.go-sys.de...
  • Page 86: Appendix D - Bluegate Server Configuration Example

    Unencrypted communication with the BlueBox is only possible from the following networks: • 10.0.0.0/8 Class A network • 172.16.0.0/12 Class B network • 192.168.0.0/16 Class C network Page 86 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0 Fax: -58080-11 www.go-sys.de info@go-sys.de...
  • Page 87: Appendix E - Measurement Data Transmission With The Program Usbimport

    <Start>. The program USBImport is part of the BlueBox PC Software. strictly spoken: USB storage device note upper and lower case Page 87 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0 Fax: -58080-11 www.go-sys.de...
  • Page 88: Appendix F - Opening Of A Bluebox Housing

    3. Open the housing by hinging the cover from the back to the front. In the cover there is the mainboard. This work must be carried out by qualified persons using suitable tools. Page 88 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0...
  • Page 89: Appendix G - Older Power Supply 150 W Switch 110/230 Vac

    3. Open the housing by lifting the cover from front to back top. ∗ As shown in Appendix F – Opening of a BlueBox Housing on the previous page. Page 89 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0...
  • Page 90 Slide switch to the right  230 VAC Slide switch to the left  110 VAC Push the slide of the switch with a suitable tool in the desired position. Page 90 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0...
  • Page 91: Appendix H - Mainboard Connections Bluebox T4

    B l u e B o x – M a i n b o a r d C o n n e c t i o n s T 4 Appendix H – Mainboard Connections BlueBox T4 BlueBox serial number starting from T40200...
  • Page 92 B l u e B o x – M a i n b o a r d C o n n e c t i o n s T 4 BlueBox serial number up to T40199 Page 92 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0...
  • Page 93: Appendix I - Mainboard Connections Bluebox T4 Basic

    B l u e B o x – M a i n b o a r d C o n n e c t i o n s T 4 B a s i c Appendix I – Mainboard Connections BlueBox T4 Basic...
  • Page 94 B l u e B o x – M a i n b o a r d C o n n e c t i o n s T 4 B a s i c BlueBox serial number up to T40199 Page 94 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0...
  • Page 95: Appendix J - Status Messages

    There is also a status message with the status number 57, which refers to an exceeded calibration interval of the clear water calibration of a spectrometer and is marked orange in the tile display. Page 95 / 96 GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0...
  • Page 96: Appendix K - Eu Declaration Of Conformity Bluebox T4

    B l u e B o x – E U D e c l a r a t i o n o f C o n f o r m i t y Appendix K – EU Declaration of Conformity BlueBox T4...