K7Dd Information Area - Omron K7DD User Manual

Power line data generator
Hide thumbs Also See for K7DD:
Table of Contents

Advertisement

7 Communications
7-7-4

K7DD Information Area

Specify the address to access each variable.
Variable
Variable name
address
H'C000 to
Reserved
H'C002
H'C003
Major Revision
H'C004
Minor Revision
H'C005 to
Serial Number
H'C006
H'C007 to
Reserved
H'C009
H'C00A to
Product Model
H'C019
H'C01A to
Product Code
H'C01D
H'C01E to
Reserved
H'FFFF
7 - 24
Do not access.
Indicates a major revision of the firmware version.
Example: H'0001 for version 1.2
Indicates a minor revision of the firmware version.
Example: H'0002 for version 1.2
This is the parameter exclusive to communications. It is a product-unique serial
number.
H'00000000 to H'FFFFFFFF (0 to 4294967295)
Variable address H'C005 is the more-significant digit and H'C006 is the less-significant
digit.
Do not access.
This is the parameter exclusive to communications.
Indicates a model of the K7DD in ASCII code.
The model is left-aligned. The remaining areas are filled with ASCII space codes
(H'20).
(Example)
When the model is K7DD-PQMA, H'4B3744442D50514D4120...
When the model is K7DD-PQMD, H'4B3744442D50514D4420...
This is the parameter exclusive to communications.
This is a JAN/EAN code for the K7DD.
4549734776646: K7DD-PQMA
4549734776653: K7DD-PQMD
Example:
When the code is read for the K7DD, it becomes
H'0XXXXXXXXXXXXX00, with H'0 appended to the most-significant digit
and H'00 appended to the least-significant digit.
Variable address H'C01A is the most-significant digit and H'C01D is the
least-significant digit.
Do not access.
Hexadecimal values are expressed by H'**.
Description
Power Line Data Generator User's Manual (N233)

Advertisement

Table of Contents
loading