Omron K7DD User Manual page 107

Power line data generator
Hide thumbs Also See for K7DD:
Table of Contents

Advertisement

I
fnd .[
Set the alarm threshold (critical) for the fundamental amplitude of
the measurement target.
The alarm will be turned ON if the fundamental amplitude exceeds
this threshold (critical).
I
fnd .{
Set the alarm threshold (warning) for the current fundamental
amplitude of the measurement target.
The alarm will be turned ON if the fundamental amplitude exceeds
this threshold (warning).
I
thd .[
Set the alarm threshold (critical) for the current total harmonic
distortion of the measurement target.
The alarm will be turned ON if the current total harmonic distortion
exceeds this threshold (critical).
Power Line Data Generator User's Manual (N233)
Current Fundamental Amplitude Critical Threshold
Setting-related page
4-2 Feature Measurement (P. 4-3)
4-3 Simplified Threshold Settings (P. 4-4)
Current Fundamental Amplitude Warning Threshold
Setting-related page
4-2 Feature Measurement (P. 4-3)
4-3 Simplified Threshold Settings (P. 4-4)
Current Total Harmonic Distortion Critical Threshold
Setting-related page
4-2 Feature Measurement (P. 4-3)
6 Using K7DD Parameters
Valid setting
Range
range
5 A
0.000 to 7.779 (A)
25 A
0.0 to 38.9 (A)
100 A
0.0 to 155.6 (A)
200 A
0.0 to 311.2 (A)
400 A
0.0 to 622.3 (A)
Valid setting
Range
range
5 A
0.000 to 7.779 (A)
25 A
0.0 to 38.9 (A)
100 A
0.0 to 155.6 (A)
200 A
0.0 to 311.2 (A)
400 A
0.0 to 622.3 (A)
Valid setting
Range
range
---
0.0 to 100.0 (%)
6