5
Installation
5.5
Installing the fieldbus junction box
5- Montage_Feldbusverteiler
Installing the fieldbus junction box
5500
Installing the fieldbus junction box
5.5
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
5-6
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
The fieldbus junction box CAN-Adapter is installed in the slot used to
hold expansion cards.
Lever the cover off using a suita-
ble screwdriver.
Make sure that no foreign bodies
fall into the open slot.
Remove the small cover grille.
Press the small cover grille back
on to the small part of the slot.
Screw the spacer bolts into the
slot's mounting lugs.
Insert the CAN Adapter into the
slot.
Turn the screws into the thread on
the spacer bolts.
Connect the female D-Sub socket
into the X6 connector on the servo
amplifier.