Signal States - Pilz PMCtendo DD5 Operating Manual

Servo amplifiers
Hide thumbs Also See for PMCtendo DD5:
Table of Contents

Advertisement

4
Function description
4.3
Control element
4.3.3.2

Signal states

4- ][Funktion_STO_Signale_DD5
Signal states
STO-ENABLE
0 V
0 V
24 V
24 V
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
4-16
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
If the safety function STO is not required, 24 VDC must always be
present at the input STO-ENABLE.
Servo amplifier states when using STO-ENABLE:
ENABLE
0 V
24 V
0 V
24 V
The safety function STO may only be activated once the motor has
stopped rotating (setpoint = 0 V, speed = 0 min
= 0 V).
The following sequence must be maintained if the drive is to use con-
trolled braking:
1. Controlled braking of the drive (speed setpoint = 0 V)
2. Disable the servo amplifier if speed = 0 min
3. If a suspended load is present, use an additional mechanical measure
to block the drive
4. Activate safety function (STO-ENABLE = 0 V)
Fig. 4-6:
Safety function STO
Message on display
-S-
F27
Device ID, e.g. B. 06
Device ID, e.g. E06
Motor torque
No
No
No
Yes
-1
, input ENABLE (X3/12)
-1
(ENABLE = 0 V)