6
Wiring
6.3
Wiring guidelines
6.3.2

Connection cables

6- ][Verdr_Leiterquerschnitte_DD5
Connection cables
Connection
Mains voltage AC
DC intermediate circuit
Brake resistor
Motor cables without
choke, max. 25 m
Motor cables with choke, 25
– 50 m*
Resolver, thermal switch,
max.100 m*
Encoder, thermal switch,
Max. 50 m*
Incremental encoder, ther-
mal switch,
Max. 25 m
Analogue inputs, AGND,
max 30 m
Digital inputs and outputs,
BTB, DGND, max. 30 m
Holding brake (motor):
+24 V/DGND
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
6-8
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
Single-axis systems
We recommend the following cable cross sections in accordance with
EN 60204:
Pin designation
X0
X8
X9
X9
X2
X1
X1
X3
X3
X9
X4
* North America: max. 39 m length, Europe: up to max. length
Cable cross section
1.5 mm²
1.5 mm²
1.5 mm²
1 mm²
4x2x0.25 mm²
7x2x0.25 mm²
8x2x0.25 mm²
0.25 mm²
0.5 mm²
2
Min. 0.75 mm
Max. 2.5 mm²
Conditions
600 V
1000 V, shielded for lengths
> 20 cm
600 V, shielded,
C < 150 pF/m
600 V, shielded,
C < 150 pF/m
Twisted pair,
shielded, C < 120 pF/m
Twisted pair, shielded
Twisted pair, shielded
Twisted pair, shielded
600 V, shielded, check volt-
age drop
Check voltage drop