Wiring
6.7
Control element
6.7.4

Analogue inputs

6- ][Verdr_Leiterquerschnitte_Verweis
Analogue inputs
][Verdr_AI_DD5
Connector X3
Input circuit
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
6-26
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
Under "Connection cables", please note the requirements for the:
Cable cross sections
Insulation material
Connector pin assignment
Pin
Designation
3
ANALOG-IN1+
4
ANALOG-IN1-
5
ANALOG-IN2+
6
ANALOG-IN2-
7
AGND
Connection
Description
Analogue input 1+
Analogue input 1-
Analogue input 2+
Analogue input 2-
Reference earth for analogue inputs
Analogue input
- Signal range –10 ... +10 V
- Referenced to earth: Always con-
nect AGND (X3/7) to CNC-GND on
the control system
- Twisted pair, shielded
- Shield connection on the front plate