Stop Category 2 - Pilz PMCtendo DD5 Operating Manual

Servo amplifiers
Hide thumbs Also See for PMCtendo DD5:
Table of Contents

Advertisement

4
Function description
4.6
Implementation of stop categories
4.6.3

Stop Category 2

4- ][Funktion_Stopp_2
Stop Category 2
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
Motor output P
M
Up to 2.5 kW
2.5 kW - 5 kW
5 kW - 10 kW
10 kW - 20 kW
20 kW - 40 kW
P
= (M
* n
) / 9550
M
0
n
where:
P
: Motor output [kW]
M
M
: Standstill torque [Nm]
0
n
: Rated speed [1/min]
n
The machine receives the operational stop command (disable) and
brakes the drive using the set braking ramp (STOPMODE and ACT-
FAULT parameters set to "1").
The drive is braked in a controlled manner as it comes to a stop. If the
speed VEL0 (see timing diagram in the section entitled "Switch on/
switch off behaviour") drops below the set value, the holding brake is
applied and the inverted rectifier is shut down. In this case, the mains
voltage is maintained.
If the mains is switched off, not only is a controlledbraking procedure
initiated but the mains voltage is galv a nically isolated from theholding
brake after a delay, which can be set on the timer.
Motor circuit brake resistor R
27 Ω (20 W) 1000 V
8.2 Ω (50 W) 1000 V
2.7 Ω (110 W) 1000 V
1 Ω (300 W) 1000 V
0.33 Ω (600 W) 1000 V
M
4-53