Figure 232. Installing the riser assembly
Step 5.
Connect the cable of the serial port module to the serial-port-module connector on the system
board assembly. For the location of the connector, refer to
on page
35.
After you finish
1. Complete the parts replacement. See
2. To enable the serial port module, do one of the following according to the installed operating system:
• For Linux operating system:
Open the ipmitool and enter the following command to disable the Serial over LAN (SOL) feature:
-I lanplus -H IP -U USERID -P PASSW0RD sol deactivate
• For Microsoft Windows operating system:
a. Open the ipmitool and enter the following command to disable the SOL feature:
-I lanplus -H IP -U USERID -P PASSW0RD sol deactivate
b. Open Windows PowerShell and enter the following command to disable the Emergency
Management Services (EMS) feature:
Bcdedit /ems no
c. Restart the server to ensure that the EMS setting takes effect.
Top cover replacement
Follow instructions in this section to remove and install the top cover.
Remove the top cover
Follow instructions in this section to remove the top cover.
S014
ThinkSystem SR650 V3 User Guide
266
"Complete the parts replacement" on page
"System-board-assembly connectors"
269.