Firmware and driver download: You might need to update the firmware or driver after replacing a
component.
• Go to
https://datacentersupport.lenovo.com/products/servers/thinksystem/sr650v3/7d75/downloads/driver-
list/
to see the latest firmware and driver updates for your server.
• Go to
"Update the firmware" on page 445
Watch the procedure
A video of this procedure is available at YouTube:
BmyijyY0-lNvapM4fTV5Gf
Procedure
Step 1.
Touch the static-protective package that contains the new part to any unpainted surface on the
outside of the server. Then, take the new part out of the package and place it on a static-protective
surface.
Step 2.
(Optional) Adjust the retainer on the M.2 backplane to accommodate the particular size of the M.2
drive you wish to install.
Figure 88. M.2 retainer adjustment
a.
Press both sides of the retainer.
b.
Move the retainer forward until it is in the large opening of the keyhole.
c.
Take the retainer out of the keyhole.
d.
Insert the retainer into the correct keyhole.
e.
Press both sides of the retainer.
f.
Slide the retainer backwards (toward the small opening of the keyhole) until it is seated in
place.
Step 3.
Locate the connector on the M.2 backplane.
Notes:
• Your M.2 backplane might look different from the following illustrations, but the installation
method is the same.
• Some M.2 backplanes support two identical M.2 drives. Install the M.2 drive in slot 0 first.
for more information on firmware updating tools.
.
https://www.youtube.com/playlist?list=PLYV5R7hVcs-
.
Chapter 5
Hardware replacement procedures