h.
If your server has a CFF adapter or a RAID flash power module installed on the front of the
chassis, remove it first.
"Remove an internal RAID/HBA/expander adapter" on page 120
"Remove a RAID flash power module from the chassis" on page 198
i.
Record where the cables are connected to the system board assembly; then, disconnect all
the cables.
j.
Remove any of the following components that are installed on the system board assembly and
put them in a safe, static-protective place.
"Remove a system fan" on page 255
"Remove the system fan cage" on page 259
"Remove a memory module" on page 136
"Processor and heat sink replacement (trained technician only)" on page 176
"Remove the CMOS battery" on page 90
"Remove a riser assembly" on page 155
"Remove the OCP module" on page 149
k.
Pull out the power supplies slightly. Ensure that they are disconnected from the system board
assembly.
Step 2.
Remove the system board assembly.
Figure 218. System board assembly removal
a.
Lift the two lifting handles at the same time.
b.
Slide the system board assembly towards the front of the chassis until it stops.
c.
Tilt and lift the system board assembly out of the chassis.
Step 3.
Separate the system I/O board from the processor board.
Note: To prevent the contact of the system I/O board from damage, pinch and lift the plunger on
the system I/O board upward a little and pull out the system I/O board outward. During the entire
pulling action, ensure that the system I/O board remains as horizontal as possible.
.
Chapter 5
Hardware replacement procedures
249