CAUTION:
Hazardous energy present. Voltages with hazardous energy might cause heating when shorted with
metal, which might result in spattered metal, burns, or both.
S017
CAUTION:
Hazardous moving fan blades nearby. Keep fingers and other body parts away.
Attention:
• Read
"Installation Guidelines" on page 55
work safely.
• For proper cooling and airflow, reinstall the air baffle before you turn on the server. Operating the server
with the air baffle removed might damage server components.
Procedure
Note: The illustrated air baffle is a standard air baffle. The installation method is the same for the GPU air
baffle.
Step 1.
Refer to
"Thermal rules" on page 69
Step 2.
(Optional) If the 1U standard heat sink or T-shape performance heat sink is installed, install the air
baffle filler to fill the gap between the heat sink and the air baffle.
Note: The following illustration shows the air baffle upside down.
ThinkSystem SR650 V3 User Guide
88
and
"Safety inspection checklist" on page 56
to select the appropriate air baffle for your server.
to ensure that you