Lenovo ThinkSystem SR650 V3 7D75 User Manual page 189

Hide thumbs Also See for ThinkSystem SR650 V3 7D75:
Table of Contents

Advertisement

c.
If your server comes with an air baffle or a middle cage, remove it first.
"Remove the air baffle" on page 85
"Remove the middle drive cage and drive backplanes" on page 144
d.
Remove the system fan cage.
Step 2.
Remove the PHM from the system board assembly.
Notes:
• Do not touch the contacts on the bottom of the processor.
• Keep the processor socket clean from any object to prevent possible damages.
Figure 140. Removing a standard PHM
a.
Fully loosen the Torx T30 nuts on the PHM in the removal sequence shown on the heat-
sink label.
b.
Rotate the anti-tilt wire bails inward.
c.
Carefully lift the PHM from the processor socket. If the PHM cannot be fully lifted out of the
socket, further loosen the Torx T30 nuts and try lifting the PHM again.
"Remove the system fan cage" on page
Chapter 5
259.
.
Hardware replacement procedures
179

Advertisement

Table of Contents
loading

This manual is also suitable for:

Thinksystem sr650 v3 7d76Thinksystem sr650 v3 7d77