• Power off the server and peripheral devices and disconnect the power cords and all external cables. See
"Power off the server" on page
• Prevent exposure to static electricity, which might lead to system halt and loss of data, by keeping static-
sensitive components in their static-protective packages until installation, and handling these devices with
an electrostatic-discharge wrist strap or other grounding system.
• Before you remove or make changes to drives, drive controllers (including controllers that are integrated
on the system board assembly), drive backplanes or drive cables, back up all important data that is stored
on drives.
• Before you remove any component of a RAID array (drive, RAID card, etc.), back up all RAID configuration
information.
• If one or more NVMe solid-state drives are to be removed, it is recommended to disable them beforehand
via the operating system.
Watch the procedure
A video of this procedure is available at YouTube:
BmyijyY0-lNvapM4fTV5Gf
Procedure
Step 1.
Make preparation for the task.
a.
If the server is installed in a rack, slide the server out on its rack slide rails to gain access to the
top cover, or remove the server from the rack. See
b.
Remove the top cover. See
c.
Disconnect cables from the rear drive backplane.
d.
Remove all the installed drives and fillers (if any) from the drive bays. See
drive" on page
Step 2.
Remove the rear drive cage.
Figure 193. Removing the 4 x 2.5-inch rear drive cage
a.
Twist and pull out the blue plungers.
ThinkSystem SR650 V3 User Guide
222
73.
.
"Remove the top cover" on page
82.
https://www.youtube.com/playlist?list=PLYV5R7hVcs-
"Remove the server from rack" on page
266.
73.
"Remove a hot-swap