Nikon SMZ25 Instruction Manual page 76

Research stereo microscope
Hide thumbs Also See for SMZ25:
Table of Contents

Advertisement

 Eyepiece
Name
Eyepiece
Model
C-W10XB
Magnification
10x
Field number
22
 Episcopic illuminator
Name
Coaxial Epi Illuminator
Model
P2-CIA
Magnification
1x
Episcopic
• Episcopic illumination
illumination
through a two-branch
fiber
• Light source: C-FLED2
LED Light Source for
Fiber Illuminator (Refer
to the instruction
manual for the light
source.)
 Epi fluorescence attachment
Name
Epi Fluorescence Attachment
Model
P2-EFLI
Magnification
1x
Epi-fl
• Attachment of filter cubes to the internal turret
illumination
• Up to four filter cubes can be attached.
• Turret switching: Knob rotation method
• Light source: HG Precentered Fiber Illuminator
C-HGFI/C-HGFIE (Refer to the instruction manual
for the light source.)
 Remote control device
Name
Remote Controller
Model
P2-RC
• Focus operation, zoom
Function, etc.
operation, etc.
• Connected to the P2-CTLA
Control Box
• For details, see Chapter 8, "10.1
P2-RC Remote Controller."
 Relay device
Name
Relay Box
Model
P2-RLY
Function, etc.
• Relay of signals for motorized control of a device or
detection of the device status
• For details, see Chapter 8, "11.3 P2-RLY Relay
Box."
Chapter 5
Specifications
Eyepiece
C-W15X
15x
16
Flexible Double Arm
Fiber Illumination Unit
C-FDF
• Episcopic illumination
through fiber branched
into two
• Light source: C-FLED2
LED Light Source for
Fiber Illuminator (Refer
to the instruction
manual for the light
source.)
• Used together with
C-FIDH Fiber Holder
Foot Switch
AZ-FSW
• Focus operation, zoom
operation
• Connected to the P2-CTLA
Control Box
62
Eyepiece
C-W20X
20x
12.5
Ring Fiber Illumination
Unit
P2-FIR
• Episcopic illumination
through fiber
positioned like a ring
• Light source: C-FLED2
LED Light Source for
Fiber Illuminator (Refer
to the instruction
manual for the light
source.)
Motorized Epi Fluorescence Attachment
P2-EFLM
1x
• Attachment of filter cubes to the internal turret
• Up to four filter cubes can be attached.
• Turret switching: Motorized
• Light source: HG Precentered Fiber Illuminator
C-HGFI/C-HGFIE (Refer to the instruction manual
for the light source.)
Photo Release
AZ-PCR
• Image capture using a DS
camera
• Connected to the AZ-FSW Foot
Switch
Relay Cable
P2-RLYC
• Relay of status detection signals with the SMZ18
Zooming Body and RELAY of the P2-CTLB Control
Box connected
Eyepiece
C-W30X
30x
7
LED Ring Illumination
Unit 2
P2-FIRL2
• Episcopic illumination
through an LED ring
(Refer to the
instruction manual for
the P2-FIRL2 LED
Ring Illumination Unit
2.)