Tubes; P2-Terg 100/ P2-Terg 50 Trinocular Tilting Tube; P2-Tl100 Trinocular Tube L - Nikon SMZ25 Instruction Manual

Research stereo microscope
Hide thumbs Also See for SMZ25:
Table of Contents

Advertisement

6

Tubes

This microscope system can be used with the tubes listed in the table below.
Attach the 10x, 15x, 20x, or 30x eyepiece to the binocular sleeve. Then, attach a camera such as a DS camera to the vertical
tube using an adapter.
The tube is equipped with the optical path switching lever. This allows the optical path to be switched during observation using
the eyepiece and capture images using the DS camera. The distribution ratio of the light amount depends on the tube type.

P2-TERG 100/ P2-TERG 50 Trinocular Tilting Tube

Tube
P2-TERG 100 Trinocular Tilting
Tube
P2-TERG 50 Trinocular Tilting Tube

P2-TL100 Trinocular Tube L

* The light amount of the left eye is always 100%. The light from the optical path of the right eye is diverged to the vertical tube. (An
image in the right eye's optical path is captured.)
P2-TERG 100/ P2-TERG 50 Trinocular Tilting Tube
6.1
The P2-TERG 100/ P2-TERG 50 is an ergonomic tube that
enables the angle of depression to be adjusted.
The angle can be continuously changed by moving the binocular
part as indicated by the arrow in the figure.
Adjust the angle to facilitate microscopy.
The eye level can be changed also by turning the binocular part 180°.
Angle of depression: 0 to 30° (continuously variable)
For the division of the light amount with the optical path switching
lever, see the table above.
Notes on adjusting the angle of depression
• Do not apply excessive force to the binocular part during depression angle adjustment. It may cause unexpected failure or
malfunction.
• When moving the binocular part, be careful not to catch your fingers in the rotary section at the bottom of the binocular part.
P2-TL100 Trinocular Tube L
6.2
Angle of depression: 10°
For the distribution ratio of the light amount with the optical path switching lever, see the table above.
Chapter 8
Functions and Operations of the Devices
Optical path
switching lever
Distribution of light with optical path switching (%)
Lever position
Pulled out
Pushed in
Pulled out
Pushed in
Pulled out
Pushed in
P2-TL100 Trinocular Tube L
Binocular part (BINO)
Left
100
100
100
100
100
100
Adjusting the angle of depression
105
Optical path
switching lever
Vertical tube
(PHOTO)*
Right
100
0
0
100
100
0
50
50
100
0
0
100