File Structure - Agilent Technologies 8711C Service Manual

Rf network analyzers and tuner analyzer
Table of Contents

Advertisement

File Structure

he program disk contains several di erent les in addition to the main program le. he
following list describes the les found on the performance test software disk.
CAL871XC
his is the main program le.
Cfg xxxx
his is the con guration le. he variable
name or
program such as:
le directories and paths
test equipment serial numbers
HP-IB addresses
types of test equipment
other optional choices
If more than one con guration le exists on the disk, the program will prompt
you to select a speci c con guration le to load. If none exists, the program
will create a default le.
P1D xxxx
he cal factor le for the HP 8481D sensor. he variable
last four digits of the HP 8481D or HP 8484A sensor's serial number.
P2A xxxx
he cal factor le for the HP 8482A sensor. he variable
last four digits of the HP 8482A sensor's serial number.
P3A xxxx
he cal factor le for the HP 8483A sensor. he variable
last four digits of the HP 8483A sensor's serial number.
Stp xxxx
he actual attenuation values for the external 10 dB step attenuator. he
variable
Attenuator values are measured at 30 MHz on an accurate system (such as an
HP 8902A Option 050).
Pd5 xxxx
he actual value of the 20 dB 50 attenuator as measured by an accurate
system. Values are attenuation versus frequency. he variable
the last four digits in the attenuator's serial number.
Pd7 xxxx
he actual value of the 20 dB 75 attenuator as measured by an accurate
system. Values are attenuation versus frequency. he variable
the last four digits in the attenuator's serial number.
d11Cxxxx
he data le that holds the analyzer's test results (in this case an HP 8711C).
he variable
number. he le \d12Cxxxx" holds data for an HP 8712C, \d13Cxxxx" for an
HP 8713C, etc.
CurrDU x
he data le that holds the test results of the most recently tested analyzer
regardless of model or serial number. he variable
character 0 to 9.
INS ALL
his program is not needed but will help speed the installation of the LIF
version program. It will automatically copy the required les into the desired
location.
1-14
Performance T ests
(default). his le contains all the con guration setups for the
Dflt
represents the last four digits in the attenuator's serial number.
xxxx
represents the last four digits in the analyzer's serial
xxxx
represents any user-de ned
xxxx
represents the
xxxx
represents the
xxxx
represents the
xxxx
can represent any
x
represents
xxxx
represents
xxxx