Front Drive Installation; Figure 40. Back Panel Shipping Screws - Intel M50FCP2UR Integration And Service Manual

Table of Contents

Advertisement

Intel® Server System M50FCP2UR System Integration and Service Guide
3. Once aligned, press the riser card assembly straight down into the riser slot (see Letter A).
4. Using the two static screw heads on the riser bracket, secure the riser card assembly to the server
board (see Letter B). Tighten to 5 in-lb.
5. Connect any required cables to the add-in card. See your add-in card documentation for additional
information.
6. Reinstall the air duct (see
7. Reinstall the system top cover (see
Note: To transport a fully integrated system, Intel highly recommends that the system include six shipping
screws (not included) installed to the system back panel (see
with additional support by reducing possible chassis flex and minimizing possible sag of the base plate.
Installed screws should meet the following specifications: flat head, 6–32 thread, 3.75 mm length
3.6

Front Drive Installation

The Intel® Server System M50FCP2UR family has support for the following front drive bay configuration
options.
Up to 8 hot-swap drives (iPC M50FCP2UR208), expandable to 16 or 24 2.5" drives with optional
accessory kits installed.
o 2.5" SSD
o SATA / SAS / NVMe
Up to 12 hot-swap drives (iPC M50FCP2UR312):
o 3.5" HDD or 2.5" SSD
o 12 SATA / SAS HDD or SSD
o 4 NVMe SSDs + 8 SAS/SATA HDDs/SSDs
Required Tools and Supplies
3.5" Hard Disk Drives (HDD) or 2.5" Solid State Drives (SSDs)
Anti-static wrist strap and conductive workbench pad (recommended)
Phillips* head screwdriver #1
Section
2.3.2).
Section
2.2.2).

Figure 40. Back Panel Shipping Screws

Figure
40). These screws provide the chassis