Page 1
Intel® Modular Server System MFSYS25 User Guide ® A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/ Products Intel Order Number D90833-010...
Page 2
Intel in writing. Unless otherwise agreed by Intel in writing, you may not remove or alter this notice or any other notice embedded in Materials by Intel or Intel’s suppliers or licensors in any way.
See also Intel® Server Boards and Server Chassis Safety Information at http://support.intel.com/support/motherboards/server/sb/cs-010770.htm. Wichtige Sicherheitshinweise Lesen Sie zunächst sämtliche Warnund Sicherheitshinweise in diesem Dokument, bevor Sie eine der Anweisungen ausführen. Beachten Sie hierzu auch die Intel® Server Boards and Server Chassis Safety Information unter http://support.intel.com/support/ motherboards/server/sb/cs-010770.htm. Consignes de sécurité...
Reinstalling enclosure cover: To protect internal components and for proper cooling and airflow, the compute module should not be inserted into the chassis with the cover removed; operating it without the enclosure cover in place can damage system parts. Intel® Modular Server System MFSYS25 User Guide...
Tools and Supplies Needed ...................... 11 Chassis References ........................11 ® Installing the Intel Modular Server System MFSYS25 in a Rack ........11 Installation Guidelines ....................... 11 Installing Temporary Handles on System ................. 12 Mounting System in Rack ......................13 Installing and Removing Modules ..................13 Installing and Removing the Management Module, Ethernet Switch Modules and Storage Controllers ........................
Page 6
Installing a Hard Drive into the Storage Bay ................32 Removing a Hard Drive from the Storage Bay ................. 34 Installing and Removing an Intel® Compute Module ............37 Installing an Intel® Compute Module ..................37 Removing an Intel® Compute Module ..................38 Using the Server System ..................39...
Page 7
Pratiques de manipulation de l’équipement ................137 Décharges électrostatiques (ESD) ..................140 Autres risques ......................... 141 Español..........................142 Información de seguridad del servidor ..................142 Advertencias y precauciones sobre seguridad ............... 142 Aplicaciones y usos previstos ....................143 Intel® Modular Server System MFSYS25 User Guide...
Page 8
Selección de la ubicación ....................... 143 Manipulación del equipo ......................143 Advertencias el acceso al sistema ..................145 Descarga electrostática (ESD) ....................146 viii Intel® Modular Server System MFSYS25 User Guide...
Page 9
Figure 26. Removing a Drive Carrier from a Drive Bay............35 Figure 27. Removing Hard Drive from a Drive Carrier ............. 36 Figure 28. Installing an Intel® Compute Module ..............37 Figure 29. Removing an Intel® Compute Module ..............38 ®...
This chapter briefly describes the main features of the Intel Modular Server System MFSYS25. This chapter provides photographs and illustrations of the product, a features list, and diagrams showing the location of important components and connections on the server chassis.
One hot-swap I/O cooling module bay One hard drive storage enclosure bay Hard drive storage enclosure 14 hot-swap 2.5-inch SAS hard disk drives ® Intel Modular Server Control Integrated GUI for configuration and chassis management. Intel® Modular Server System MFSYS25 User Guide...
Compute modules or filler panels (six) [1 at top, 6 at bottom] Storage enclosure with hot-swap 2.5-inch SAS hard disk drives (14) [1 at upper left, 14 at lower right] I/O cooling module Figure 2. Front View of Server System Intel® Modular Server System MFSYS25 User Guide...
Page 16
Modular Server System MFSYS25 has an integrated 14-bay hot-swap 2.5-inch SAS hard disk drive storage enclosure. Storage is shared among all installed compute modules. At least one Intel® Storage Controller is required to access the shared storage. Because hard disk drives have different cooling, power, and vibration characteristics, Intel ®...
All four power supply bays must be populated with either a power supply module or a power supply blank. The power supply blank has two fans that ensure proper system cooling. Intel® Modular Server System MFSYS25 User Guide...
Page 18
Storage Controller One or two hot-swap Intel® Storage Controllers can be used with 14 hot-swap drives in the front to support hard disk drives in the chassis. One storage controller is the minimum configuration;...
Figure 4. Front Chassis Connectors and Indicators All indicator modes are described in “Diagnostic LED Information” on page Compute Module ® See the individual Intel Compute Module MFS5000SI User Guide for model-specific information. Intel® Modular Server System MFSYS25 User Guide...
Power supply module power LED – Green Power supply fault indicator LED – Amber Main Cooling Module Main cooling module fault LED – Amber Main cooling module power LED – Green Figure 5. Rear Chassis Connectors and Indicators Intel® Modular Server System MFSYS25 User Guide...
“Diagnostic LED Information” on page Hardware Requirements To avoid integration difficulties and possible system damage, your server system must meet the requirements listed in the table under “Before Powering On the Server System” on page Intel® Modular Server System MFSYS25 User Guide...
Page 22
Intel® Modular Server System MFSYS25 User Guide...
Rack ® The Intel Modular Server System MFSYS25 is designed for fixed mount rack installation only; all service events will be performed from either the front or back of the system. Caution: When removing the system from its packaging, DO NOT lift the system by the power supply or fan module handles.
MFSYS25 in a rack. ® 4. The Intel Modular Server System MFSYS25 can only be installed in a rack cabinet with perforated front and rear doors. 5. Plan device installation starting with the bottom of the rack cabinet. 6. Do not leave unused space within the rack cabinet opening; blank filler panels must be used to fill gaps and prevent recirculation of warm air.
Compute modules, management modules, switch modules, storage controllers, power modules and cooling modules should be replaced with a like component or a filler panel within two minutes. Intel® Modular Server System MFSYS25 User Guide...
Replacing a Management Module ® The Intel Modular Server System MFSYS25 ships with a management module pre- installed. If necessary, the management module may be removed and replaced by following these steps: 1. Review the safety and ESD information at the beginning of this manual and in the appendices.
AF002414 Figure 8. Installing Management Module 5. Rotate the lever handle in toward the module bay until it is latched. 6. Reconnect the Ethernet management port to the management network. Intel® Modular Server System MFSYS25 User Guide...
Installing and Removing an Ethernet Switch Module ® The Intel Modular Server System MFSYS25 ships with one Ethernet switch module pre- installed; optionally, a second switch module may be installed in the second switch module bay. Installing an Ethernet Switch Module 1.
Rotate the lever out and away from the module bay (see letter “B”) and pull the module straight out the back of the chassis (see letter “C”). AF002413 Figure 10. Removing an Ethernet Switch Module Intel® Modular Server System MFSYS25 User Guide...
Installing and Removing a Storage Controller ® The Intel Modular Server System MFSYS25 ships with one storage controller pre- installed; optionally, a second storage controller may be installed in the open storage controller bay. Installing a Storage Controller 1.
4. Rotate the lever handle in toward the module bay until it latches. Removing a Storage Controller 1. Review the safety and ESD information at the beginning of this manual and in the appendices. Intel® Modular Server System MFSYS25 User Guide...
Warning: You must replace the storage controller with a filler panel or another storage controller within two minutes. AF002430 Figure 12. Removing a Storage Controller 3. Replace the storage controller with a filler panel or another storage controller within two minutes. Intel® Modular Server System MFSYS25 User Guide...
(see letter “A” in the following figure). Push cover rearward (see letter “B”) and lift off of module (see letter “C”). AF002563 Figure 13. Removing Top Cover from Storage Controller 5. Slide the cover towards the rear of the storage controller and lift upward. Intel® Modular Server System MFSYS25 User Guide...
2. Remove the storage controller from the system. For instructions, see “Removing a Storage Controller” on page Warning: You must replace the storage controller with a filler panel or another storage controller within two minutes. Intel® Modular Server System MFSYS25 User Guide...
(see letter “A” in the following figure). Push cover rearward (see letter “B”) and lift off of module (see letter “C”). AF002563 Figure 15. Removing Top Cover from Storage Controller 5. Slide the cover towards rear of the storage controller and lift upward. Intel® Modular Server System MFSYS25 User Guide...
® The Intel Modular Server System MFSYS25 ships with two power supply modules pre- installed. A single power supply is suitable to support the power requirement for the chassis, including fan modules, storage controller, switch module, storage bay, and a single compute module.
(see letter “A” in the following figure) to release the filler module from the module bay. Slide the filler module out of the bay (see letter “B”). AF002420 Figure 17. Removing Filler Module Intel® Modular Server System MFSYS25 User Guide...
1. Review the safety and ESD information at the beginning of this manual and in the appendices. 2. Locate the power supply module to be removed. 3. Remove the power cord from both the power supply module and the power source. Intel® Modular Server System MFSYS25 User Guide...
Replacing Cooling Modules ® The Intel Modular Server System MFSYS25 ships with two main cooling modules pre- installed at the back of the chassis and one I/O cooling module at the front. Replacing a Main Cooling Module 1. Review the safety and ESD information at the beginning of this manual and in the appendices.
4. Slide the main cooling module out of the module bay Warning: Replace the cooling module with another cooling module within two minutes. AF002438 Figure 20. Removing a Main Cooling Module Intel® Modular Server System MFSYS25 User Guide...
5. Slide the replacement cooling module into the unoccupied cooling module bay (see letter “C”) until the retention latch engages. AF002439 Figure 21. Installing a Main Cooling Module Intel® Modular Server System MFSYS25 User Guide...
Installing and Removing Hard Drives ® The Intel Modular Server System MFSYS25 provides storage for installed compute modules by way of an on-board storage bay combined with a storage management module. The on-board storage bay supports the installation of up to 14 hot-swap 2.5-inch SAS hard drives that are configured through the integrated server control software.
® hard drive that is not listed in the Intel Modular Server System MFSYS25 Tested Hardware and Operating System List. Installing a Hard Drive into the Storage Bay 1. Review the safety and ESD information at the beginning of this manual and in the appendices.
4. Attach hard drive to drive carrier, using the four screws removed in the previous step. AF002428 Figure 24. Installing Hard Drive into Drive Carrier Intel® Modular Server System MFSYS25 User Guide...
1. Review the safety and ESD information at the beginning of this manual and in the appendices. 2. To avoid data corruption, ensure that the drive you intend to remove is not online and actively providing data storage to any of the installed compute modules. Intel® Modular Server System MFSYS25 User Guide...
3. Press the retaining lever on the selected drive carrier to release the drive carrier from the drive bay (see letter “A” in the following figure). Remove the drive carrier from the drive bay (see letter “B”). AF002425 Figure 26. Removing a Drive Carrier from a Drive Bay Intel® Modular Server System MFSYS25 User Guide...
5. Install either another hot-swap hard drive or a filler blank in the drive carrier. Install the drive carrier into the empty drive bay within two minutes; this step is required to maintain proper airflow throughout the chassis and to ensure proper system cooling. Intel® Modular Server System MFSYS25 User Guide...
“A” in the following figure). Insert the compute module into an open slot in the chassis and slide it in until it stops. AF002431 Figure 28. Installing an Intel® Compute Module 4. Close the release handles on the front of the compute module. Intel® Modular Server System MFSYS25 User Guide...
4. Place either a filler or another compute module in the bay within two minutes. This step is required to maintain proper airflow throughout the server system and to ensure proper system cooling. Intel® Modular Server System MFSYS25 User Guide...
® The Intel Modular Server System MFSYS25 does not have a power switch. When the chassis has at least one power supply with power cord plugged into an appropriate electrical outlet, standby power is available. With standby current, a user can remotely connect to the management module and/or power on a compute module.
Modular Server System MFSYS25, you must first properly power down all compute modules. Next, disconnect all power cables from the power source. Refer to the individual Intel® Compute Module User Guide for more information on powering down the compute module(s).
® The Intel Management Module provides a simple and intuitive browser-based graphical ® user interface that IT administrators can use to monitor and configure the Intel Modular ® Server System MFSYS25. This GUI is referred to as the Intel Modular Server Control UI.
® 2. Change the management module default static IP address if more than one Intel Modular Server System MFSYS25 is present on the network, or if the default management module IP address cannot be accessed in the installed network environment.
Management Module to an external switch using two Ethernet cables, as illustrated in the following image. Switch AF002069 ® Option 2: Connect the client system directly to the Intel Management Module using a cross-over cable, as illustrated in the following image. Cross-over Cable AF002068...
The login screen (illustrated below) will be displayed. An administrator user account is enabled for the system. This default administrator account provides access to all available management configuration settings and actions. User Account information: — Username: admin — Password: admin Intel® Modular Server System MFSYS25 User Guide...
The top menu provides quick access to multiple system views. The left navigation menu provides access to system configuration screens, reports and general setting configuration screens. The main body provides the content for the selected view or screen. Intel® Modular Server System MFSYS25 User Guide...
The system configuration screens are designed to present all available information and actions for a selected system component in the main body of the interface. The following image illustrates the layout and types of information presented on the system configuration screens. Intel® Modular Server System MFSYS25 User Guide...
® Help Intel Modular Server Control UI Help ® Top Menu Tabs Quickly switches between key sections of the Intel Modular Server Control. Left Navigation Provides direct links to configure and manage individual hardware components. Menu Main Body Displays content for selected menu item or view. For the system items, the main body is divided into four panes: the system graphic, action menu, context sensitive help, and informational tabs.
Dashboard ® The Dashboard view is displayed by default after successfully logging into the Intel Modular Server Control UI. It provides an interactive snapshot of the overall system and component health, as well as a list of all required actions and critical events. To get...
5. Recent Critical Events - Displays all recent (unacknowledged) critical events and a link to View All Events. The View All Events link redirects the IT administrator to the Events view. Figure 33. Dashboard View Intel® Modular Server System MFSYS25 User Guide...
The Chassis Front view enables an IT administrator to select the component he/she is most interested in. By default, no components are selected on the chassis in this view. Figure 34. Chassis Front View Intel® Modular Server System MFSYS25 User Guide...
IT administrator to quickly view and acknowledge new events for all system components in a single location. For more information on how to use the Events screen, refer to “Events ” on page Intel® Modular Server System MFSYS25 User Guide...
Help ® The Help link located at the top right of the banner opens the Intel Modular Server Control Help in a new window. Use the table of contents to quickly access help and tips for specific screens and functions.
Compute Module MFS5000SI ® To view current status, available actions and product details for all installed Intel Compute Module MFS5000SIs, select a specific server from the Chassis Front, or select Servers from the System left navigation menu. The selected server will be highlighted on the system graphic.
Page 66
® Intel Compute Module MFS5000SI Details The tabs displayed below the system graphic provide detailed information on the selected server. For a description of these tabs, refer to the following table. Intel® Modular Server System MFSYS25 User Guide...
® Intel Compute Module MFS5000SI Help ® To quickly access additional help regarding the Intel Compute Module MFS5000SI screen, actions, and tabs, click on the Get Help button in the Server help box located under the actions. Remote KVM & CD Remote KVM &...
9. The KVM session should start successfully. 10. To install an application from a CD, insert the CD into the remote console’s CD-ROM drive and select CD from the Devices menu. Intel® Modular Server System MFSYS25 User Guide...
The first step in assigning storage to a server is to create a storage pool or group of drives. Once a storage pool is created, virtual drives are created within the storage pool and assigned to a server. Intel® Modular Server System MFSYS25 User Guide...
This enables a single storage pool to support many virtual drives with different RAID levels. After selecting the drives for the storage pool, enter a name or label for this storage pool and click Create to continue. Intel® Modular Server System MFSYS25 User Guide...
Current health and product summary is quickly available by moving the mouse over the Health/ Information icon located on the selected storage pool. Intel® Modular Server System MFSYS25 User Guide...
ALL DATA WILL BE LOST. Identify Illuminates the hard drive ID LED, which enables easy onsite identification of the drives included in the selected storage pool. Intel® Modular Server System MFSYS25 User Guide...
Get Help button in the Storage Pool help box located under the actions. Create a Virtual Drive Once a storage pool has been created, the next step is to create a virtual drive. Key benefits of virtual drives are: Intel® Modular Server System MFSYS25 User Guide...
6. Select Wipe Master Boot Record (MBR) if an operating system will be installed on this virtual drive. This will ensure a fresh volume for partitioning. 7. Controller Affinity is available for selection if two Intel® Storage Controllers are installed in the system. This option determines the preferred storage controller to handle requests for the new virtual drive.
8. Assign or map the virtual drive to a server. A virtual drive can be assigned to any of ® the six server slots. A server does not have to be present in the Intel Modular Server System MFSYS25 for selection. This enables an IT administrator to assign virtual drives to servers that will be added to the system.
Virtual Drive Details The tabs displayed below the system graphic provide detailed information on the selected virtual drive. For a description of these tabs, refer to the following table. Intel® Modular Server System MFSYS25 User Guide...
To reassign an existing virtual drive: 1. Select the virtual drive to be edited. 2. Select Assign from the action menu. 3. The following dialog box opens. Intel® Modular Server System MFSYS25 User Guide...
4. The server assignment and drive position fields are available for modification. 5. Once all edits are complete, click Apply to continue. The new virtual drive server assignment will be displayed on the main storage screen. Intel® Modular Server System MFSYS25 User Guide...
The following figure displays the Storage screen after a virtual drive has been deleted from a storage pool which contained more than three virtual drives. Figure 45. Deleted Virtual Drive Intel® Modular Server System MFSYS25 User Guide...
Enables an IT administrator to force a drive offline remotely. Force drive is a hot spare or Offline is present if a drive is a hot spare or included in a storage included in an existing pool. storage pool) Intel® Modular Server System MFSYS25 User Guide...
Physical Drive Help To quickly access additional help regarding physical drive actions and tabs, click on the Get Help button in the Shared Drive help box located under the action box. Intel® Modular Server System MFSYS25 User Guide...
Page 82
Intel® Gigabit Ethernet Switch Module 1 and 2 To view current status, available actions and product details for all installed Intel® Gigabit Ethernet Switch Modules, select Switch under the left navigation menu heading System or select the specific switch module from the back of the system graphic. The main screen graphic will change to display the back of the system with the selected switch module highlighted in green.
Figure 47. Intel® Gigabit Ethernet Switch Module View Intel® Gigabit Ethernet Switch Module Actions The actions available for a selected switch module are displayed to the right of the system graphic. For a description of these actions, refer to the following table.
Displays current status and general Intel® Gigabit Ethernet Switch information, such as product ID, uptime, hardware and software versions, and MAC address. Events Displays all system events for the selected Intel® Gigabit Ethernet Switch. Ports Displays table of key port settings, including Port ID, VLAN ID, Enabled/ Disabled Status, Link Status Set Speed, Current Speed, VLAN Mode and Spanning Tree (STP).
Page 85
Intel® Gigabit Ethernet Switches come pre-configured with all available ports enabled in ® a single default VLAN. No additional configuration is required to connect the Intel Modular Server System MFSYS25 to a network. Two options are available to modify the default switch configuration. The Configure Ports action menu item enables an IT administrator to quickly and easily modify port and Virtual LAN (VLAN) settings.
Figure 48. Configure Ports Dialog Box Advanced Configuration The action box item, Advanced Configuration, launches a separate interface that exposes all configuration settings for the Intel® Gigabit Ethernet Switch in a new window. ® Configuration settings modified in either the Advanced Configuration or the Intel Modular Server Control UI are displayed in both interfaces.
Figure 49. Advanced Configuration Screen Intel® Storage Controller 1 and 2 To view current status, available actions and product details for all installed Intel® Storage Controllers, select the specific storage controller from the back of the system graphic. The main screen graphic will change to display the back of the system with the selected storage controller highlighted in green.
Enables remote reset of the selected Intel® Storage Controller. Expansion Port Enable/Disable server access to the external expansion port on the selected storage controller. Additional external storage options are available to the server via the expansion port. Intel® Modular Server System MFSYS25 User Guide...
Management Module ® To view current status, available actions and product details for the installed Intel Management Module, select the specific management module from the back of the system graphic. The main screen graphic will change to display the back of the system with the selected management module highlighted in green.
Enables remote reset of the selected management module. ® Intel Management Module Details The tabs displayed below the system graphic provide detailed information for the management module. For a description of these tabs, refer to the following table. Intel® Modular Server System MFSYS25 User Guide...
® Intel Management Module Help ® To quickly access additional help regarding the Intel Management Module screen, actions, and tabs, click on the Get Help button in the Management Module help box located under the actions box. ®...
One virtual drive is present. The virtual drive is named “Email” and is configured as a 30-GB RAID 5 drive. • The virtual drive “Email” is assigned to Server 1 as Drive 0. Intel® Modular Server System MFSYS25 User Guide...
• Close events: Close individual events by selecting the checkbox next to the event and clicking the Close Selected button. Once an event is closed, it is no longer displayed on this screen. Intel® Modular Server System MFSYS25 User Guide...
Navigate events: If more than 20 events are present, links to additional pages will be displayed at the top of the screen next to the rows drop-down box. Click on the page number to view additional events. Figure 53. System Event Log Screen Intel® Modular Server System MFSYS25 User Guide...
The Diagnostics feature enables an IT administrator to view and save system diagnostic information and the system event logs for select components. The Diagnostics page can be reached by selecting Reports -> Diagnostics from the left navigation menu. Intel® Modular Server System MFSYS25 User Guide...
Clicking on the Diagnostics Data will generate a download of the service information, which can be saved or opened as shown in Figure 56 Figure Figure 56. Diagnostic Data Generation Intel® Modular Server System MFSYS25 User Guide...
The Service Data window provides the IT administrator with the ability to save the dump file of the Storage Subsystem State, Switches, and All Subsystems. This file can be used to aid in troubleshooting issues with the storage and switch configurations. Figure 58. Diagnostics - Service Data Intel® Modular Server System MFSYS25 User Guide...
In Intel Modular Server Control provides a simple interface to update the system firmware from a single compressed update package released by Intel called an UFU (Unified Firmware Update). In addition to providing an easy-to-use interface to update the firmware for the entire system, this screen will display all currently installed component firmware versions, as well as current status.
Use the dialog box to change the severity of a specific event, as well as to select who to notify when the event occurs. Figure 60. Settings - Event Policies Configuration Screen Intel® Modular Server System MFSYS25 User Guide...
IP Configuration ® The IP Configuration screen enables an IT Administrator to change the Intel Management Module host name and external network access, as well as view the internal configuration. The following is a description of the settings and information found in the IP Configuration tab: •...
Settings > User Accounts from the left navigation menu. Figure 62. Settings - User Account Configuration Screen Alert Notifications The Alert Notification settings screen provides the IT administrator with the capability to set system alert notification destinations. Intel® Modular Server System MFSYS25 User Guide...
Figure 63. Settings - Alert Notification Destination Configuration Screen SNMP SNMP configuration enables the IT administrator to set the SNMP community strings and time-outs. Communities can be set to determine who gets trap notifications. Intel® Modular Server System MFSYS25 User Guide...
“<” decrements to the previous Month. b. Clicking the outside double right angle bracket “>>” increments to the next Year while clicking the outside double left angle bracket “<<” decrements to the previous Year. Intel® Modular Server System MFSYS25 User Guide...
When all Date and Time changes are complete, click the Update button in the lower left corner of the screen. This will reset the management module to enable the changes to take effect. Figure 65. Settings - System Date and Time Configuration Intel® Modular Server System MFSYS25 User Guide...
First Steps Checklist ® • Is the power LED lit on all modules installed in the Intel Modular Server System MFSYS25? • Is the chassis properly connected to an AC power source? • Are the various chassis modules fully seated? —...
• Is the power LED on? If not, re-seat the fan module. If so, check the fault LED. ® • Is the fault LED on? Check the status of the system using the Intel Modular Server Control. • Are both fan modules in error? If so, verify that the power supply modules are properly installed and connected to grounded AC outlets.
The various modules and compute modules designed for use with the Intel Modular Server System MFSYS25 provide a number of diagnostic LEDs that may aid in troubleshooting your system. A list of these LEDs, with usage descriptions for each LED, is provided in the following two tables.
On = Ethernet switch module Module Power of the Ethernet switch module front panel power on module Ethernet Switch Visible fault warning Ethernet switch Amber On = Ethernet switch module Module Fault module front panel fault Intel® Modular Server System MFSYS25 User Guide...
No network connection Solid Amber Network connection in place Blinking Amber Transmit/receive activity Right LED 10 Mbps connection (if Left LED is on or blinking) Solid Amber 100 Mbps connection Solid Green 1000 Mbps connection Intel® Modular Server System MFSYS25 User Guide...
Page 110
Intel® Modular Server System MFSYS25 User Guide...
CB Certificate & Report, (report to include all CB country national deviations) Product Safety GOST R 50377-92 Certification (Russia) Product Safety Ukraine Certification (Ukraine) Product Safety BSMI RPC Certification (Taiwan) Product Safety UL 60950 Listing (USA) Intel® Modular Server System MFSYS25 User Guide...
FCC – Part 15 Emissions (USA) Verification Product Ecology Requirements Intel has a system in place to restrict the use of banned substances in accordance with world wide product ecology regulatory requirements. Suppliers Declarations of Conformity to the banned substances must be obtained from all suppliers; and a Material Declaration Data Sheet (MDDS) must be produced to illustrate compliance.
Not having component-level certifications will impact the system-level certification cost wise and may prevent shipment of the component as a spare or accessory into a certain country. Certification of components shall be at the most current certifications standard. Intel® Modular Server System MFSYS25 User Guide...
Page 114
CE DOC (Europe) CB Certificate & Report (International) Note: CB to include all CB national deviations) Certification marks to be visible on power supply Power supply to comply with the Intel power supply specification. Component Peripheral Devices (e.g., Disk Drives, CD...
Requirement Description Y/N/D Regulatory Argentina Markings (IRAM Mark) Regulatory Australia / NZ Markings Ctick Mark N232 Regulatory Canada EMC CANADA ICES-OO3 CLASS A Markings Marking CANADA NMB-003 CLASSE A Regulatory China (CNCA) Markings Intel® Modular Server System MFSYS25 User Guide...
Page 116
(1) This device may not cause harmful interference, and (2) This device must accept interference receive, including interference that may cause undesired operation. Regulatory Country of Made in XXXX Markings Origin Mark Intel® Modular Server System MFSYS25 User Guide...
Page 117
統 電 纜 。 German: Dieses Geräte hat mehr als ein Stromkabel. Um eine Gefahr des elektrischen Schlages zu verringern trennen sie beide (2) Stromkabeln bevor Instandhaltung. Regulatory WEEE Markings Marking Regulatory China RoHS Markings Intel® Modular Server System MFSYS25 User Guide...
Page 118
Code of Regulations, Title 22, Division 4.5, Chapter 33: Best Management Practices for Perchlorate Materials. This product / part includes a battery which contains Perchlorate material. Standard icon for Power button Should be attached on power button Intel® Modular Server System MFSYS25 User Guide...
Updated product information for configurations can be found on the Intel Server Builder Web site at the following URL: http://channel.intel.com/go/serverbuilder If you do not have access to Intel’s Web address, please contact your local Intel representative. • Server chassis (base chassis is provided with power supply and fans) must be UL listed.
Page 120
Intel® Modular Server System MFSYS25 User Guide...
“as is” unless specifically provided for otherwise in any software license accompanying the software. If any Product furnished by Intel which is the subject of this Limited Warranty fails during the warranty period for reasons covered by this Limited Warranty, Intel, at its option, will: •...
Limitations of Liability Intel's responsibility under this, or any other warranty, implied or expressed, is limited to repair, replacement, or refund, as set forth above. These remedies are the sole and exclusive remedies for any breach of warranty.
Telephone Support If you cannot find the information you need on Intel's World Wide Web site (http:// www.intel.com/), call your local distributor or an Intel Customer Support representative.
Page 124
Intel® Modular Server System MFSYS25 User Guide...
To do this: 1. Unlock and remove the padlock from the back of the system if a padlock has been installed. 2. Remove and save all screws from the covers. 3. Remove the cover(s). Intel® Modular Server System MFSYS25 User Guide...
Page 126
• Provided with a properly grounded wall outlet. • Provided with sufficient space to access the power supply cord(s), because they serve as the product's main power disconnect. Intel® Modular Server System MFSYS25 User Guide...
Anschlußkabel von den I/O Anschlüssen oder Ports ab. 5. Tragen Sie ein geerdetes Antistatik Gelenkband, um elektrostatische Ladungen (ESD) über blanke Metallstellen bei der Handhabung der Komponenten zu vermeiden. 6. Schalten Sie das System niemals ohne ordnungsgemäß montiertes Gehäuse ein. Intel® Modular Server System MFSYS25 User Guide...
Page 128
Schutzhandschuhe tragen. Bei falschem Einsetzen einer neuen Batterie besteht Explosionsgefahr. Die Batterie darf nur durch denselben oder einen entsprechenden, vom Hersteller empfohlenen Batterietyp ersetzt werden. Entsorgen Sie verbrauchte Batterien den Anweisungen des Herstellers entsprechend. Intel® Modular Server System MFSYS25 User Guide...
Page 129
Telekommunikationsleitungen mit dem Modem bestehen; • "mit einer geerdeten Wechselstromsteckdose ausgerüstet sein; • "über ausreichend Platz verfügen, um Zugang zu den Netzkabeln zu gewährleisten, da der Stromanschluß des Produkts hauptsächlich über die Kabel unterbrochen wird Intel® Modular Server System MFSYS25 User Guide...
Procédez comme suit: 1. Si un cadenas a été installé sur à l'arrière du système, déverrouillez-le et retirez-le. 2. Retirez toutes les vis des panneaux et mettez-les dans un endroit sûr. 3. Retirez les panneaux. Intel® Modular Server System MFSYS25 User Guide...
Page 131
• "Muni d'une prise murale correctement mise à la terre. • "Suffisamment spacieux pour vous permettre d'accéder aux câbles d'alimentation (ceux-ci étant le seul moyen de mettre le système hors tension). Intel® Modular Server System MFSYS25 User Guide...
Para ello: 1. Desbloquee y extraiga el bloqueo de seguridad de la parte posterior del sistema, si se ha instalado uno. 2. Extraiga y guarde todos los tornillos de las tapas.Extraiga las tapas. Intel® Modular Server System MFSYS25 User Guide...
Page 133
• "Provisto de una toma de tierra correctamente instalada. • "Provisto de espacio suficiente como para acceder a los cables de alimentación, ya que éstos hacen de medio principal de desconexión del sistema. Intel® Modular Server System MFSYS25 User Guide...
1. Aprire e rimuovere il lucchetto dal retro del sistema qualora ve ne fosse uno installato. 2. Togliere e mettere in un posto sicuro tutte le viti delle coperture. 3. Togliere le coperture. Intel® Modular Server System MFSYS25 User Guide...
Page 135
• "Dotata di una presa a muro correttamente installata. • "Dotata di spazio sufficiente ad accedere ai cavi di alimentazione, i quali rappresentano il mezzo principale di scollegamento del sistema. Intel® Modular Server System MFSYS25 User Guide...
Page 136
Intel® Modular Server System MFSYS25 User Guide...
Indicates hot components or surfaces. Indicates do not touch fan blades, may result in injury. Indicates to unplug all AC power cord(s) to disconnect AC power Please recycle battery Intel® Modular Server System MFSYS25 User Guide...
To remove power from system, you must unplug the AC power cord from the wall outlet. Your system may use more than one AC power cord. Make sure all AC power cords are Intel® Modular Server System MFSYS25 User Guide...
Turn off all peripheral devices connected to this product. • Turn off the system by pressing the power button to off. • Disconnect the AC power by unplugging all AC power cords from the system or wall outlet. Intel® Modular Server System MFSYS25 User Guide...
Always handle boards carefully. They can be extremely sensitive to ESD. Hold boards only by their edges. After removing a board from its protective wrapper or from the server, place the board component side up on a grounded, static free surface. Use a Intel® Modular Server System MFSYS25 User Guide...
Caution: To avoid risk of radiation exposure and/or personal injury: • Do not open the enclosure of any laser peripheral or device • Laser peripherals or devices have are not user serviceable • Return to manufacturer for servicing Intel® Modular Server System MFSYS25 User Guide...
Deutsch Sicherheitshinweise für den Server Das vorliegende Dokument bezieht sich auf Intel® Serverplatinen, Intel® Servergehäuse (Standfuß und Rack) sowie installierte Peripheriegeräte. Es enthält Warnungen und Vorsichtsmaßnahmen zur Vermeidung von Gefahren durch Verletzung, Stromschlag, Feuer und Beschädigungen von Geräten. Lesen Sie diese Dokument daher sorgfältig, bevor Sie Ihr Intel®...
Verwenden Sie mechanische oder andere geeignete Hilfsmittel zum Transportieren oder Anheben von Geräten. • Entfernen Sie alle Komponenten, die sich leicht abnehmen lassen, um das Gewicht zu reduzieren und die Handhabung zu erleichtern. Intel® Modular Server System MFSYS25 User Guide...
Page 144
Typ entspricht. Jedes Netzteil im System muß über ein eigenes Netzkabel angeschlossen werden. Einige Netzteile von Intel Servern verwenden Nullleitersicherungen. Vorsicht ist geboten im Umgang mit Netzteilen, welche Nullleitersicherungen verwenden, um das Risiko eines elektrischen Schlages zu vermeiden Das Netzteil in diesem Produkt enthält keine Teile, die vom Benutzer gewartet werden...
Einbauen von Hot-Plug-Komponenten sorgfältig vor, um nicht mit heißen Komponenten in Berührung zu kommen. Vorsicht: Berühren Sie nicht die rotierenden Lüfterflügel, um Verletzungen zu vermeiden. Falls Ihr System mit eine Lüfterabdeckung besitzt, darf es nicht ohne diese Abdeckung betrieben werden. Intel® Modular Server System MFSYS25 User Guide...
Ausbau aus dem Server mit der Bauelementseite nach oben auf eine geerdete, statisch entladene Unterlage.Verwenden Sie dazu, sofern verfügbar, eine leitfahige Schaumstoffunterlage, aber niche die Schutzhülle der Platine. Ziehen Sie die Platine nicht über eine Fläche. Intel® Modular Server System MFSYS25 User Guide...
• Öffnen Sie keinesfalls das Gehäuse von Laser-Peripheriegeräten oder Laser- Komponenten. • Laser-Peripheriegeräte oder -Komponenten besitzen keine für den Benutzer wartungsbedürftigen Teile. • Schicken Sie das Gerät für Wartungsarbeiten an den Hersteller zurück. Intel® Modular Server System MFSYS25 User Guide...
Français Consignes de sécurité sur le serveur Ce document s’applique aux cartes serveur Intel®, au châssis de serveur Intel® (sur pieds et sur rack) et aux périphériques installés. Pour réduire les risques de dommages corporels, d’électrocution, d’incendie et de dommages matériels, lisez ce document et respectez tous les avertissements et précautions mentionnés dans ce guide avant...
• Utilisez l’assistance mécanique ou toute autre assistance appropriée lorsque vous déplacez et soulevez le matériel. • Pour réduire le poids en vue de faciliter la manipulation, retirez tout composant amovible. Intel® Modular Server System MFSYS25 User Guide...
Page 150
Vous devez les débrancher avant d’ouvrir le châssis, d’ajouter ou de supprimer un composant non connectable à chaud. Les alimentations de certains serveurs Intel sont munies de doubles fusibles pôle/neutre: veuillez observer les précautions d'usage afin d'éviter tout risque d'eléctrocution.
Page 151
Attention: Pour éviter de vous blesser, ne touchez pas les pales de ventilateur en mouvement. Si votre système est fourni avec une protection sur le ventilateur, ne mettez pas le système en route sans la protection en place. Intel® Modular Server System MFSYS25 User Guide...
Utilisez si possible un tapi de mousse conducteru, mais pas l’emballage de la carte. Veillez à ce que la carte ne glisse sur aucune surface. Intel® Modular Server System MFSYS25 User Guide...
Attention: Pour éviter tout risque d’exposition aux rayonnements et/ou de dommage personnel: • N’ouvrez pas l’enceinte d’un périphérique laser. • Les périphériques laser ne sont pas réparables par l’utilisateur. • Retournez-les au fabricant en cas de problème. Intel® Modular Server System MFSYS25 User Guide...
Español Información de seguridad del servidor ® Este documento se aplica a las tarjetas de servidor de Intel , los gabinetes de servidor de ® Intel (montaje en rack y en pedestal) y los dispositivos periféricos. Para reducir el riesgo de daños corporales, descargas eléctricas, fuego y en el equipo, lea este documento y...
Utilice medios mecánicos u otros que sean adecuados al trasladar o levantar el equipo. • Para que el peso sea menor para manipularlo con más facilidad, extraiga los componentes que sean de fácil extracción. Intel® Modular Server System MFSYS25 User Guide...
Page 156
CA estén desenchufado antes de abrir le gabinete, agregar o extraer cualquier componente que no es de conexión en funcionamiento. Algunas fuentes de alimentación de electricidad de los servidores de Intel utilizan el polo neutral del fuselaje. Para evitar riesgos de choques eléctricos use precauciones al trabajar con las fuentes de alimentación que utilizan el polo neutral de fuselaje.
Precaución: Para evitar posibles daños, no toque las aspas en movimiento de los ventiladores. Si el sistema se le ha suministrado con una protección para el ventilador, asegúrese de que cuando esté funcionando el sistema la protección esté en su sitio. Intel® Modular Server System MFSYS25 User Guide...
Utilice una almohadilla de espuma conductora si dispone de ella, pero nunca el envoltorio de la tarjeta. No deslice la tarjeta sobre ninguna superficie. Intel® Modular Server System MFSYS25 User Guide...
Page 159
Precaución: Para evitar el riesgo de la exposición a radiaciones o de daños personales: • No abra la caja de ningún periférico o dispositivo láser • Los periféricos o dispositivos láser no pueden ser reparados por el usuario • Haga que el fabricante los repare. Intel® Modular Server System MFSYS25 User Guide...
Need help?
Do you have a question about the MFSYS25 and is the answer not in the manual?
Questions and answers