A Guide for Technically Qualified Assemblers of Intel
Identified Subassemblies/
Products
Intel Order Number D90833-010

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MFSYS25 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Intel MFSYS25

  • Page 1 Intel® Modular Server System MFSYS25 User Guide ® A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/ Products Intel Order Number D90833-010...
  • Page 2 Intel in writing. Unless otherwise agreed by Intel in writing, you may not remove or alter this notice or any other notice embedded in Materials by Intel or Intel’s suppliers or licensors in any way.
  • Page 3: Safety Information

    See also Intel® Server Boards and Server Chassis Safety Information at http://support.intel.com/support/motherboards/server/sb/cs-010770.htm. Wichtige Sicherheitshinweise Lesen Sie zunächst sämtliche Warnund Sicherheitshinweise in diesem Dokument, bevor Sie eine der Anweisungen ausführen. Beachten Sie hierzu auch die Intel® Server Boards and Server Chassis Safety Information unter http://support.intel.com/support/ motherboards/server/sb/cs-010770.htm. Consignes de sécurité...
  • Page 4: Warnings

    Reinstalling enclosure cover: To protect internal components and for proper cooling and airflow, the compute module should not be inserted into the chassis with the cover removed; operating it without the enclosure cover in place can damage system parts. Intel® Modular Server System MFSYS25 User Guide...
  • Page 5: Table Of Contents

    Tools and Supplies Needed ...................... 11 Chassis References ........................11 ® Installing the Intel Modular Server System MFSYS25 in a Rack ........11 Installation Guidelines ....................... 11 Installing Temporary Handles on System ................. 12 Mounting System in Rack ......................13 Installing and Removing Modules ..................13 Installing and Removing the Management Module, Ethernet Switch Modules and Storage Controllers ........................
  • Page 6 Installing a Hard Drive into the Storage Bay ................32 Removing a Hard Drive from the Storage Bay ................. 34 Installing and Removing an Intel® Compute Module ............37 Installing an Intel® Compute Module ..................37 Removing an Intel® Compute Module ..................38 Using the Server System ..................39...
  • Page 7 Pratiques de manipulation de l’équipement ................137 Décharges électrostatiques (ESD) ..................140 Autres risques ......................... 141 Español..........................142 Información de seguridad del servidor ..................142 Advertencias y precauciones sobre seguridad ............... 142 Aplicaciones y usos previstos ....................143 Intel® Modular Server System MFSYS25 User Guide...
  • Page 8 Selección de la ubicación ....................... 143 Manipulación del equipo ......................143 Advertencias el acceso al sistema ..................145 Descarga electrostática (ESD) ....................146 viii Intel® Modular Server System MFSYS25 User Guide...
  • Page 9 Figure 26. Removing a Drive Carrier from a Drive Bay............35 Figure 27. Removing Hard Drive from a Drive Carrier ............. 36 Figure 28. Installing an Intel® Compute Module ..............37 Figure 29. Removing an Intel® Compute Module ..............38 ®...
  • Page 10 Figure 44. Assign Virtual Drive ....................66 Figure 45. Deleted Virtual Drive....................67 Figure 46. Physical Drives ....................... 68 Figure 47. Intel® Gigabit Ethernet Switch Module View ............71 Figure 48. Configure Ports Dialog Box ..................74 Figure 49. Advanced Configuration Screen ................75 Figure 50.
  • Page 11 Table 15. Management Module Action Menu................78 Table 16. Management Module Tabs..................79 Table 17. Fans and Power Supplies Tabs ................80 Table 18. Diagnostic LEDs....................... 96 Table 19. NIC LEDs ......................... 97 Intel® Modular Server System MFSYS25 User Guide...
  • Page 12 Intel® Modular Server System MFSYS25 User Guide...
  • Page 13: Server System Features

    This chapter briefly describes the main features of the Intel Modular Server System MFSYS25. This chapter provides photographs and illustrations of the product, a features list, and diagrams showing the location of important components and connections on the server chassis.
  • Page 14: Table 1. Chassis Features

    One hot-swap I/O cooling module bay One hard drive storage enclosure bay Hard drive storage enclosure 14 hot-swap 2.5-inch SAS hard disk drives ® Intel Modular Server Control Integrated GUI for configuration and chassis management. Intel® Modular Server System MFSYS25 User Guide...
  • Page 15: Major Components

    Compute modules or filler panels (six) [1 at top, 6 at bottom] Storage enclosure with hot-swap 2.5-inch SAS hard disk drives (14) [1 at upper left, 14 at lower right] I/O cooling module Figure 2. Front View of Server System Intel® Modular Server System MFSYS25 User Guide...
  • Page 16 Modular Server System MFSYS25 has an integrated 14-bay hot-swap 2.5-inch SAS hard disk drive storage enclosure. Storage is shared among all installed compute modules. At least one Intel® Storage Controller is required to access the shared storage. Because hard disk drives have different cooling, power, and vibration characteristics, Intel ®...
  • Page 17: Rear View

    All four power supply bays must be populated with either a power supply module or a power supply blank. The power supply blank has two fans that ensure proper system cooling. Intel® Modular Server System MFSYS25 User Guide...
  • Page 18 Storage Controller One or two hot-swap Intel® Storage Controllers can be used with 14 hot-swap drives in the front to support hard disk drives in the chassis. One storage controller is the minimum configuration;...
  • Page 19: Front Chassis Connectors And Indicators

    Figure 4. Front Chassis Connectors and Indicators All indicator modes are described in “Diagnostic LED Information” on page Compute Module ® See the individual Intel Compute Module MFS5000SI User Guide for model-specific information. Intel® Modular Server System MFSYS25 User Guide...
  • Page 20: Back Chassis Connectors And Indicators

    Power supply module power LED – Green Power supply fault indicator LED – Amber Main Cooling Module Main cooling module fault LED – Amber Main cooling module power LED – Green Figure 5. Rear Chassis Connectors and Indicators Intel® Modular Server System MFSYS25 User Guide...
  • Page 21: Hardware Requirements

    “Diagnostic LED Information” on page Hardware Requirements To avoid integration difficulties and possible system damage, your server system must meet the requirements listed in the table under “Before Powering On the Server System” on page Intel® Modular Server System MFSYS25 User Guide...
  • Page 22 Intel® Modular Server System MFSYS25 User Guide...
  • Page 23: Hardware Installations And Upgrades

    Rack ® The Intel Modular Server System MFSYS25 is designed for fixed mount rack installation only; all service events will be performed from either the front or back of the system. Caution: When removing the system from its packaging, DO NOT lift the system by the power supply or fan module handles.
  • Page 24: Installing Temporary Handles On System

    MFSYS25 in a rack. ® 4. The Intel Modular Server System MFSYS25 can only be installed in a rack cabinet with perforated front and rear doors. 5. Plan device installation starting with the bottom of the rack cabinet. 6. Do not leave unused space within the rack cabinet opening; blank filler panels must be used to fill gaps and prevent recirculation of warm air.
  • Page 25: Mounting System In Rack

    Compute modules, management modules, switch modules, storage controllers, power modules and cooling modules should be replaced with a like component or a filler panel within two minutes. Intel® Modular Server System MFSYS25 User Guide...
  • Page 26: Installing And Removing The Management Module, Ethernet Switch Modules And Storage Controllers

    Replacing a Management Module ® The Intel Modular Server System MFSYS25 ships with a management module pre- installed. If necessary, the management module may be removed and replaced by following these steps: 1. Review the safety and ESD information at the beginning of this manual and in the appendices.
  • Page 27: Figure 7. Removing Management Module

    AF002436 Figure 7. Removing Management Module Intel® Modular Server System MFSYS25 User Guide...
  • Page 28: Figure 8. Installing Management Module

    AF002414 Figure 8. Installing Management Module 5. Rotate the lever handle in toward the module bay until it is latched. 6. Reconnect the Ethernet management port to the management network. Intel® Modular Server System MFSYS25 User Guide...
  • Page 29: Installing And Removing An Ethernet Switch Module

    Installing and Removing an Ethernet Switch Module ® The Intel Modular Server System MFSYS25 ships with one Ethernet switch module pre- installed; optionally, a second switch module may be installed in the second switch module bay. Installing an Ethernet Switch Module 1.
  • Page 30: Figure 10. Removing An Ethernet Switch Module

    Rotate the lever out and away from the module bay (see letter “B”) and pull the module straight out the back of the chassis (see letter “C”). AF002413 Figure 10. Removing an Ethernet Switch Module Intel® Modular Server System MFSYS25 User Guide...
  • Page 31: Installing And Removing A Storage Controller

    Installing and Removing a Storage Controller ® The Intel Modular Server System MFSYS25 ships with one storage controller pre- installed; optionally, a second storage controller may be installed in the open storage controller bay. Installing a Storage Controller 1.
  • Page 32: Figure 11. Installing A Storage Controller

    4. Rotate the lever handle in toward the module bay until it latches. Removing a Storage Controller 1. Review the safety and ESD information at the beginning of this manual and in the appendices. Intel® Modular Server System MFSYS25 User Guide...
  • Page 33: Figure 12. Removing A Storage Controller

    Warning: You must replace the storage controller with a filler panel or another storage controller within two minutes. AF002430 Figure 12. Removing a Storage Controller 3. Replace the storage controller with a filler panel or another storage controller within two minutes. Intel® Modular Server System MFSYS25 User Guide...
  • Page 34: Installing And Removing The Backup Battery

    (see letter “A” in the following figure). Push cover rearward (see letter “B”) and lift off of module (see letter “C”). AF002563 Figure 13. Removing Top Cover from Storage Controller 5. Slide the cover towards the rear of the storage controller and lift upward. Intel® Modular Server System MFSYS25 User Guide...
  • Page 35: Removing A Backup Battery

    2. Remove the storage controller from the system. For instructions, see “Removing a Storage Controller” on page Warning: You must replace the storage controller with a filler panel or another storage controller within two minutes. Intel® Modular Server System MFSYS25 User Guide...
  • Page 36: Figure 15. Removing Top Cover From Storage Controller

    (see letter “A” in the following figure). Push cover rearward (see letter “B”) and lift off of module (see letter “C”). AF002563 Figure 15. Removing Top Cover from Storage Controller 5. Slide the cover towards rear of the storage controller and lift upward. Intel® Modular Server System MFSYS25 User Guide...
  • Page 37: Installing And Removing A Power Supply Module

    ® The Intel Modular Server System MFSYS25 ships with two power supply modules pre- installed. A single power supply is suitable to support the power requirement for the chassis, including fan modules, storage controller, switch module, storage bay, and a single compute module.
  • Page 38: Installing A Power Supply Module

    (see letter “A” in the following figure) to release the filler module from the module bay. Slide the filler module out of the bay (see letter “B”). AF002420 Figure 17. Removing Filler Module Intel® Modular Server System MFSYS25 User Guide...
  • Page 39: Removing A Power Supply Module

    1. Review the safety and ESD information at the beginning of this manual and in the appendices. 2. Locate the power supply module to be removed. 3. Remove the power cord from both the power supply module and the power source. Intel® Modular Server System MFSYS25 User Guide...
  • Page 40: Replacing Cooling Modules

    Replacing Cooling Modules ® The Intel Modular Server System MFSYS25 ships with two main cooling modules pre- installed at the back of the chassis and one I/O cooling module at the front. Replacing a Main Cooling Module 1. Review the safety and ESD information at the beginning of this manual and in the appendices.
  • Page 41: Figure 20. Removing A Main Cooling Module

    4. Slide the main cooling module out of the module bay Warning: Replace the cooling module with another cooling module within two minutes. AF002438 Figure 20. Removing a Main Cooling Module Intel® Modular Server System MFSYS25 User Guide...
  • Page 42: Figure 21. Installing A Main Cooling Module

    5. Slide the replacement cooling module into the unoccupied cooling module bay (see letter “C”) until the retention latch engages. AF002439 Figure 21. Installing a Main Cooling Module Intel® Modular Server System MFSYS25 User Guide...
  • Page 43: Replacing The I/O Cooling Module

    Installing and Removing Hard Drives ® The Intel Modular Server System MFSYS25 provides storage for installed compute modules by way of an on-board storage bay combined with a storage management module. The on-board storage bay supports the installation of up to 14 hot-swap 2.5-inch SAS hard drives that are configured through the integrated server control software.
  • Page 44: Installing A Hard Drive Into The Storage Bay

    ® hard drive that is not listed in the Intel Modular Server System MFSYS25 Tested Hardware and Operating System List. Installing a Hard Drive into the Storage Bay 1. Review the safety and ESD information at the beginning of this manual and in the appendices.
  • Page 45: Figure 24. Installing Hard Drive Into Drive Carrier

    4. Attach hard drive to drive carrier, using the four screws removed in the previous step. AF002428 Figure 24. Installing Hard Drive into Drive Carrier Intel® Modular Server System MFSYS25 User Guide...
  • Page 46: Removing A Hard Drive From The Storage Bay

    1. Review the safety and ESD information at the beginning of this manual and in the appendices. 2. To avoid data corruption, ensure that the drive you intend to remove is not online and actively providing data storage to any of the installed compute modules. Intel® Modular Server System MFSYS25 User Guide...
  • Page 47: Figure 26. Removing A Drive Carrier From A Drive Bay

    3. Press the retaining lever on the selected drive carrier to release the drive carrier from the drive bay (see letter “A” in the following figure). Remove the drive carrier from the drive bay (see letter “B”). AF002425 Figure 26. Removing a Drive Carrier from a Drive Bay Intel® Modular Server System MFSYS25 User Guide...
  • Page 48: Figure 27. Removing Hard Drive From A Drive Carrier

    5. Install either another hot-swap hard drive or a filler blank in the drive carrier. Install the drive carrier into the empty drive bay within two minutes; this step is required to maintain proper airflow throughout the chassis and to ensure proper system cooling. Intel® Modular Server System MFSYS25 User Guide...
  • Page 49: Installing And Removing An Intel® Compute Module

    “A” in the following figure). Insert the compute module into an open slot in the chassis and slide it in until it stops. AF002431 Figure 28. Installing an Intel® Compute Module 4. Close the release handles on the front of the compute module. Intel® Modular Server System MFSYS25 User Guide...
  • Page 50: Removing An Intel® Compute Module

    4. Place either a filler or another compute module in the bay within two minutes. This step is required to maintain proper airflow throughout the server system and to ensure proper system cooling. Intel® Modular Server System MFSYS25 User Guide...
  • Page 51: Using The Server System

    ® The Intel Modular Server System MFSYS25 does not have a power switch. When the chassis has at least one power supply with power cord plugged into an appropriate electrical outlet, standby power is available. With standby current, a user can remotely connect to the management module and/or power on a compute module.
  • Page 52: Monitoring The Server System

    Modular Server System MFSYS25, you must first properly power down all compute modules. Next, disconnect all power cables from the power source. Refer to the individual Intel® Compute Module User Guide for more information on powering down the compute module(s).
  • Page 53: Configuring The Server Chassis

    ® The Intel Management Module provides a simple and intuitive browser-based graphical ® user interface that IT administrators can use to monitor and configure the Intel Modular ® Server System MFSYS25. This GUI is referred to as the Intel Modular Server Control UI.
  • Page 54: Required Configuration For Systems

    ® 2. Change the management module default static IP address if more than one Intel Modular Server System MFSYS25 is present on the network, or if the default management module IP address cannot be accessed in the installed network environment.
  • Page 55: Remote Client System Requirements

    Management Module to an external switch using two Ethernet cables, as illustrated in the following image. Switch AF002069 ® Option 2: Connect the client system directly to the Intel Management Module using a cross-over cable, as illustrated in the following image. Cross-over Cable AF002068...
  • Page 56: Intel ® Modular Server Control

    The login screen (illustrated below) will be displayed. An administrator user account is enabled for the system. This default administrator account provides access to all available management configuration settings and actions. User Account information: — Username: admin — Password: admin Intel® Modular Server System MFSYS25 User Guide...
  • Page 57: Layout And Key Navigation Features

    The top menu provides quick access to multiple system views. The left navigation menu provides access to system configuration screens, reports and general setting configuration screens. The main body provides the content for the selected view or screen. Intel® Modular Server System MFSYS25 User Guide...
  • Page 58: Figure 31. Intel ® Modular Server Control General Layout

    The system configuration screens are designed to present all available information and actions for a selected system component in the main body of the interface. The following image illustrates the layout and types of information presented on the system configuration screens. Intel® Modular Server System MFSYS25 User Guide...
  • Page 59: Figure 32. Intel ® Modular Server Control Configuration Screen Layout

    ® Help Intel Modular Server Control UI Help ® Top Menu Tabs Quickly switches between key sections of the Intel Modular Server Control. Left Navigation Provides direct links to configure and manage individual hardware components. Menu Main Body Displays content for selected menu item or view. For the system items, the main body is divided into four panes: the system graphic, action menu, context sensitive help, and informational tabs.
  • Page 60: Intel ® Modular Server Control Views

    Dashboard ® The Dashboard view is displayed by default after successfully logging into the Intel Modular Server Control UI. It provides an interactive snapshot of the overall system and component health, as well as a list of all required actions and critical events. To get...
  • Page 61: Figure 33. Dashboard View

    5. Recent Critical Events - Displays all recent (unacknowledged) critical events and a link to View All Events. The View All Events link redirects the IT administrator to the Events view. Figure 33. Dashboard View Intel® Modular Server System MFSYS25 User Guide...
  • Page 62: Figure 34. Chassis Front View

    The Chassis Front view enables an IT administrator to select the component he/she is most interested in. By default, no components are selected on the chassis in this view. Figure 34. Chassis Front View Intel® Modular Server System MFSYS25 User Guide...
  • Page 63: Figure 35. Chassis Back View

    IT administrator to quickly view and acknowledge new events for all system components in a single location. For more information on how to use the Events screen, refer to “Events ” on page Intel® Modular Server System MFSYS25 User Guide...
  • Page 64: Intel ® Modular Server Control Left Menu Items

    Help ® The Help link located at the top right of the banner opens the Intel Modular Server Control Help in a new window. Use the table of contents to quickly access help and tips for specific screens and functions.
  • Page 65: Figure 36. Intel ® Compute Module Mfs5000Si View

    Compute Module MFS5000SI ® To view current status, available actions and product details for all installed Intel Compute Module MFS5000SIs, select a specific server from the Chassis Front, or select Servers from the System left navigation menu. The selected server will be highlighted on the system graphic.
  • Page 66 ® Intel Compute Module MFS5000SI Details The tabs displayed below the system graphic provide detailed information on the selected server. For a description of these tabs, refer to the following table. Intel® Modular Server System MFSYS25 User Guide...
  • Page 67: Table 4. Server Tabs

    ® Intel Compute Module MFS5000SI Help ® To quickly access additional help regarding the Intel Compute Module MFS5000SI screen, actions, and tabs, click on the Get Help button in the Server help box located under the actions. Remote KVM & CD Remote KVM &...
  • Page 68: Figure 37. Server Action - Remote Kvm & Cd

    9. The KVM session should start successfully. 10. To install an application from a CD, insert the CD into the remote console’s CD-ROM drive and select CD from the Devices menu. Intel® Modular Server System MFSYS25 User Guide...
  • Page 69: Figure 38. Initial Storage Configuration Screen

    The first step in assigning storage to a server is to create a storage pool or group of drives. Once a storage pool is created, virtual drives are created within the storage pool and assigned to a server. Intel® Modular Server System MFSYS25 User Guide...
  • Page 70: Figure 39. Create Storage Pool Dialog Box

    This enables a single storage pool to support many virtual drives with different RAID levels. After selecting the drives for the storage pool, enter a name or label for this storage pool and click Create to continue. Intel® Modular Server System MFSYS25 User Guide...
  • Page 71: Figure 40. Create Storage Pool Dialog Box Example

    Current health and product summary is quickly available by moving the mouse over the Health/ Information icon located on the selected storage pool. Intel® Modular Server System MFSYS25 User Guide...
  • Page 72: Figure 41. Storage Screen With A Storage Pool Present

    ALL DATA WILL BE LOST. Identify Illuminates the hard drive ID LED, which enables easy onsite identification of the drives included in the selected storage pool. Intel® Modular Server System MFSYS25 User Guide...
  • Page 73: Table 6. Storage Pool Tabs

    Get Help button in the Storage Pool help box located under the actions. Create a Virtual Drive Once a storage pool has been created, the next step is to create a virtual drive. Key benefits of virtual drives are: Intel® Modular Server System MFSYS25 User Guide...
  • Page 74: Figure 42. Create Virtual Drive Dialog Box

    6. Select Wipe Master Boot Record (MBR) if an operating system will be installed on this virtual drive. This will ensure a fresh volume for partitioning. 7. Controller Affinity is available for selection if two Intel® Storage Controllers are installed in the system. This option determines the preferred storage controller to handle requests for the new virtual drive.
  • Page 75: Figure 43. Virtual Drive Screen

    8. Assign or map the virtual drive to a server. A virtual drive can be assigned to any of ® the six server slots. A server does not have to be present in the Intel Modular Server System MFSYS25 for selection. This enables an IT administrator to assign virtual drives to servers that will be added to the system.
  • Page 76: Table 7. Virtual Drive Action Menu

    Virtual Drive Details The tabs displayed below the system graphic provide detailed information on the selected virtual drive. For a description of these tabs, refer to the following table. Intel® Modular Server System MFSYS25 User Guide...
  • Page 77: Table 8. Virtual Drive Tabs

    To reassign an existing virtual drive: 1. Select the virtual drive to be edited. 2. Select Assign from the action menu. 3. The following dialog box opens. Intel® Modular Server System MFSYS25 User Guide...
  • Page 78: Figure 44. Assign Virtual Drive

    4. The server assignment and drive position fields are available for modification. 5. Once all edits are complete, click Apply to continue. The new virtual drive server assignment will be displayed on the main storage screen. Intel® Modular Server System MFSYS25 User Guide...
  • Page 79: Figure 45. Deleted Virtual Drive

    The following figure displays the Storage screen after a virtual drive has been deleted from a storage pool which contained more than three virtual drives. Figure 45. Deleted Virtual Drive Intel® Modular Server System MFSYS25 User Guide...
  • Page 80: Figure 46. Physical Drives

    Enables an IT administrator to force a drive offline remotely. Force drive is a hot spare or Offline is present if a drive is a hot spare or included in a storage included in an existing pool. storage pool) Intel® Modular Server System MFSYS25 User Guide...
  • Page 81: Table 10. Physical Drive Tabs

    Physical Drive Help To quickly access additional help regarding physical drive actions and tabs, click on the Get Help button in the Shared Drive help box located under the action box. Intel® Modular Server System MFSYS25 User Guide...
  • Page 82 Intel® Gigabit Ethernet Switch Module 1 and 2 To view current status, available actions and product details for all installed Intel® Gigabit Ethernet Switch Modules, select Switch under the left navigation menu heading System or select the specific switch module from the back of the system graphic. The main screen graphic will change to display the back of the system with the selected switch module highlighted in green.
  • Page 83: Figure 47. Intel® Gigabit Ethernet Switch Module View

    Figure 47. Intel® Gigabit Ethernet Switch Module View Intel® Gigabit Ethernet Switch Module Actions The actions available for a selected switch module are displayed to the right of the system graphic. For a description of these actions, refer to the following table.
  • Page 84: Table 11. Switch Module Action Menu

    Displays current status and general Intel® Gigabit Ethernet Switch information, such as product ID, uptime, hardware and software versions, and MAC address. Events Displays all system events for the selected Intel® Gigabit Ethernet Switch. Ports Displays table of key port settings, including Port ID, VLAN ID, Enabled/ Disabled Status, Link Status Set Speed, Current Speed, VLAN Mode and Spanning Tree (STP).
  • Page 85 Intel® Gigabit Ethernet Switches come pre-configured with all available ports enabled in ® a single default VLAN. No additional configuration is required to connect the Intel Modular Server System MFSYS25 to a network. Two options are available to modify the default switch configuration. The Configure Ports action menu item enables an IT administrator to quickly and easily modify port and Virtual LAN (VLAN) settings.
  • Page 86: Figure 48. Configure Ports Dialog Box

    Figure 48. Configure Ports Dialog Box Advanced Configuration The action box item, Advanced Configuration, launches a separate interface that exposes all configuration settings for the Intel® Gigabit Ethernet Switch in a new window. ® Configuration settings modified in either the Advanced Configuration or the Intel Modular Server Control UI are displayed in both interfaces.
  • Page 87: Figure 49. Advanced Configuration Screen

    Figure 49. Advanced Configuration Screen Intel® Storage Controller 1 and 2 To view current status, available actions and product details for all installed Intel® Storage Controllers, select the specific storage controller from the back of the system graphic. The main screen graphic will change to display the back of the system with the selected storage controller highlighted in green.
  • Page 88: Figure 50. Intel® Storage Controller View

    Enables remote reset of the selected Intel® Storage Controller. Expansion Port Enable/Disable server access to the external expansion port on the selected storage controller. Additional external storage options are available to the server via the expansion port. Intel® Modular Server System MFSYS25 User Guide...
  • Page 89: Table 14. Storage Controller Tabs

    Management Module ® To view current status, available actions and product details for the installed Intel Management Module, select the specific management module from the back of the system graphic. The main screen graphic will change to display the back of the system with the selected management module highlighted in green.
  • Page 90: Figure 51. Intel ® Management Module View

    Enables remote reset of the selected management module. ® Intel Management Module Details The tabs displayed below the system graphic provide detailed information for the management module. For a description of these tabs, refer to the following table. Intel® Modular Server System MFSYS25 User Guide...
  • Page 91: Table 16. Management Module Tabs

    ® Intel Management Module Help ® To quickly access additional help regarding the Intel Management Module screen, actions, and tabs, click on the Get Help button in the Management Module help box located under the actions box. ®...
  • Page 92: Reports

    One virtual drive is present. The virtual drive is named “Email” and is configured as a 30-GB RAID 5 drive. • The virtual drive “Email” is assigned to Server 1 as Drive 0. Intel® Modular Server System MFSYS25 User Guide...
  • Page 93: Figure 52. Storage Layout

    • Close events: Close individual events by selecting the checkbox next to the event and clicking the Close Selected button. Once an event is closed, it is no longer displayed on this screen. Intel® Modular Server System MFSYS25 User Guide...
  • Page 94: Figure 53. System Event Log Screen

    Navigate events: If more than 20 events are present, links to additional pages will be displayed at the top of the screen next to the rows drop-down box. Click on the page number to view additional events. Figure 53. System Event Log Screen Intel® Modular Server System MFSYS25 User Guide...
  • Page 95: Figure 54. Event Policy Record Window

    The Diagnostics feature enables an IT administrator to view and save system diagnostic information and the system event logs for select components. The Diagnostics page can be reached by selecting Reports -> Diagnostics from the left navigation menu. Intel® Modular Server System MFSYS25 User Guide...
  • Page 96: Figure 55. Diagnostics

    Clicking on the Diagnostics Data will generate a download of the service information, which can be saved or opened as shown in Figure 56 Figure Figure 56. Diagnostic Data Generation Intel® Modular Server System MFSYS25 User Guide...
  • Page 97: Figure 57. Diagnostic Data File

    The Service Data window provides the IT administrator with the ability to save the dump file of the Storage Subsystem State, Switches, and All Subsystems. This file can be used to aid in troubleshooting issues with the storage and switch configurations. Figure 58. Diagnostics - Service Data Intel® Modular Server System MFSYS25 User Guide...
  • Page 98: Settings

    In Intel Modular Server Control provides a simple interface to update the system firmware from a single compressed update package released by Intel called an UFU (Unified Firmware Update). In addition to providing an easy-to-use interface to update the firmware for the entire system, this screen will display all currently installed component firmware versions, as well as current status.
  • Page 99: Figure 60. Settings - Event Policies Configuration Screen

    Use the dialog box to change the severity of a specific event, as well as to select who to notify when the event occurs. Figure 60. Settings - Event Policies Configuration Screen Intel® Modular Server System MFSYS25 User Guide...
  • Page 100: Figure 61. Settings - Ip Configuration

    IP Configuration ® The IP Configuration screen enables an IT Administrator to change the Intel Management Module host name and external network access, as well as view the internal configuration. The following is a description of the settings and information found in the IP Configuration tab: •...
  • Page 101: Figure 62. Settings - User Account Configuration Screen

    Settings > User Accounts from the left navigation menu. Figure 62. Settings - User Account Configuration Screen Alert Notifications The Alert Notification settings screen provides the IT administrator with the capability to set system alert notification destinations. Intel® Modular Server System MFSYS25 User Guide...
  • Page 102: Figure 63. Settings - Alert Notification Destination Configuration Screen

    Figure 63. Settings - Alert Notification Destination Configuration Screen SNMP SNMP configuration enables the IT administrator to set the SNMP community strings and time-outs. Communities can be set to determine who gets trap notifications. Intel® Modular Server System MFSYS25 User Guide...
  • Page 103: Figure 64. Settings - Snmp Configuration Screen

    “<” decrements to the previous Month. b. Clicking the outside double right angle bracket “>>” increments to the next Year while clicking the outside double left angle bracket “<<” decrements to the previous Year. Intel® Modular Server System MFSYS25 User Guide...
  • Page 104: Figure 65. Settings - System Date And Time Configuration

    When all Date and Time changes are complete, click the Update button in the lower left corner of the screen. This will reset the management module to enable the changes to take effect. Figure 65. Settings - System Date and Time Configuration Intel® Modular Server System MFSYS25 User Guide...
  • Page 105: Troubleshooting

    First Steps Checklist ® • Is the power LED lit on all modules installed in the Intel Modular Server System MFSYS25? • Is the chassis properly connected to an AC power source? • Are the various chassis modules fully seated? —...
  • Page 106: Chassis Fan Module Not Functioning

    • Is the power LED on? If not, re-seat the fan module. If so, check the fault LED. ® • Is the fault LED on? Check the status of the system using the Intel Modular Server Control. • Are both fan modules in error? If so, verify that the power supply modules are properly installed and connected to grounded AC outlets.
  • Page 107: Cannot Connect A Compute Module To A Storage Controller

    The various modules and compute modules designed for use with the Intel Modular Server System MFSYS25 provide a number of diagnostic LEDs that may aid in troubleshooting your system. A list of these LEDs, with usage descriptions for each LED, is provided in the following two tables.
  • Page 108: Table 18. Diagnostic Leds

    On = Ethernet switch module Module Power of the Ethernet switch module front panel power on module Ethernet Switch Visible fault warning Ethernet switch Amber On = Ethernet switch module Module Fault module front panel fault Intel® Modular Server System MFSYS25 User Guide...
  • Page 109: Table 19. Nic Leds

    No network connection Solid Amber Network connection in place Blinking Amber Transmit/receive activity Right LED 10 Mbps connection (if Left LED is on or blinking) Solid Amber 100 Mbps connection Solid Green 1000 Mbps connection Intel® Modular Server System MFSYS25 User Guide...
  • Page 110 Intel® Modular Server System MFSYS25 User Guide...
  • Page 111: A Product Regulatory Requirements

    CB Certificate & Report, (report to include all CB country national deviations) Product Safety GOST R 50377-92 Certification (Russia) Product Safety Ukraine Certification (Ukraine) Product Safety BSMI RPC Certification (Taiwan) Product Safety UL 60950 Listing (USA) Intel® Modular Server System MFSYS25 User Guide...
  • Page 112: Electro Magnetic Compatibility (Emc) / Harmonic Requirements

    FCC – Part 15 Emissions (USA) Verification Product Ecology Requirements Intel has a system in place to restrict the use of banned substances in accordance with world wide product ecology regulatory requirements. Suppliers Declarations of Conformity to the banned substances must be obtained from all suppliers; and a Material Declaration Data Sheet (MDDS) must be produced to illustrate compliance.
  • Page 113: Component Regulatory Requirements Needed To Support System Level Certifications

    Not having component-level certifications will impact the system-level certification cost wise and may prevent shipment of the component as a spare or accessory into a certain country. Certification of components shall be at the most current certifications standard. Intel® Modular Server System MFSYS25 User Guide...
  • Page 114 CE DOC (Europe) CB Certificate & Report (International) Note: CB to include all CB national deviations) Certification marks to be visible on power supply Power supply to comply with the Intel power supply specification. Component Peripheral Devices (e.g., Disk Drives, CD...
  • Page 115: Product Regulatory Compliance And Safety Markings

    Requirement Description Y/N/D Regulatory Argentina Markings (IRAM Mark) Regulatory Australia / NZ Markings Ctick Mark N232 Regulatory Canada EMC CANADA ICES-OO3 CLASS A Markings Marking CANADA NMB-003 CLASSE A Regulatory China (CNCA) Markings Intel® Modular Server System MFSYS25 User Guide...
  • Page 116 (1) This device may not cause harmful interference, and (2) This device must accept interference receive, including interference that may cause undesired operation. Regulatory Country of Made in XXXX Markings Origin Mark Intel® Modular Server System MFSYS25 User Guide...
  • Page 117 統 電 纜 。 German: Dieses Geräte hat mehr als ein Stromkabel. Um eine Gefahr des elektrischen Schlages zu verringern trennen sie beide (2) Stromkabeln bevor Instandhaltung. Regulatory WEEE Markings Marking Regulatory China RoHS Markings Intel® Modular Server System MFSYS25 User Guide...
  • Page 118 Code of Regulations, Title 22, Division 4.5, Chapter 33: Best Management Practices for Perchlorate Materials. This product / part includes a battery which contains Perchlorate material. Standard icon for Power button Should be attached on power button Intel® Modular Server System MFSYS25 User Guide...
  • Page 119: Product Regulatory Documentation Requirements

    Updated product information for configurations can be found on the Intel Server Builder Web site at the following URL: http://channel.intel.com/go/serverbuilder If you do not have access to Intel’s Web address, please contact your local Intel representative. • Server chassis (base chassis is provided with power supply and fans) must be UL listed.
  • Page 120 Intel® Modular Server System MFSYS25 User Guide...
  • Page 121: B Warranty

    “as is” unless specifically provided for otherwise in any software license accompanying the software. If any Product furnished by Intel which is the subject of this Limited Warranty fails during the warranty period for reasons covered by this Limited Warranty, Intel, at its option, will: •...
  • Page 122: Warranty Limitations And Exclusions

    Limitations of Liability Intel's responsibility under this, or any other warranty, implied or expressed, is limited to repair, replacement, or refund, as set forth above. These remedies are the sole and exclusive remedies for any breach of warranty.
  • Page 123: Telephone Support

    Telephone Support If you cannot find the information you need on Intel's World Wide Web site (http:// www.intel.com/), call your local distributor or an Intel Customer Support representative.
  • Page 124 Intel® Modular Server System MFSYS25 User Guide...
  • Page 125: C Installation/Assembly Safety Instructions

    To do this: 1. Unlock and remove the padlock from the back of the system if a padlock has been installed. 2. Remove and save all screws from the covers. 3. Remove the cover(s). Intel® Modular Server System MFSYS25 User Guide...
  • Page 126 • Provided with a properly grounded wall outlet. • Provided with sufficient space to access the power supply cord(s), because they serve as the product's main power disconnect. Intel® Modular Server System MFSYS25 User Guide...
  • Page 127: Deutsch

    Anschlußkabel von den I/O Anschlüssen oder Ports ab. 5. Tragen Sie ein geerdetes Antistatik Gelenkband, um elektrostatische Ladungen (ESD) über blanke Metallstellen bei der Handhabung der Komponenten zu vermeiden. 6. Schalten Sie das System niemals ohne ordnungsgemäß montiertes Gehäuse ein. Intel® Modular Server System MFSYS25 User Guide...
  • Page 128 Schutzhandschuhe tragen. Bei falschem Einsetzen einer neuen Batterie besteht Explosionsgefahr. Die Batterie darf nur durch denselben oder einen entsprechenden, vom Hersteller empfohlenen Batterietyp ersetzt werden. Entsorgen Sie verbrauchte Batterien den Anweisungen des Herstellers entsprechend. Intel® Modular Server System MFSYS25 User Guide...
  • Page 129 Telekommunikationsleitungen mit dem Modem bestehen; • "mit einer geerdeten Wechselstromsteckdose ausgerüstet sein; • "über ausreichend Platz verfügen, um Zugang zu den Netzkabeln zu gewährleisten, da der Stromanschluß des Produkts hauptsächlich über die Kabel unterbrochen wird Intel® Modular Server System MFSYS25 User Guide...
  • Page 130: Français

    Procédez comme suit: 1. Si un cadenas a été installé sur à l'arrière du système, déverrouillez-le et retirez-le. 2. Retirez toutes les vis des panneaux et mettez-les dans un endroit sûr. 3. Retirez les panneaux. Intel® Modular Server System MFSYS25 User Guide...
  • Page 131 • "Muni d'une prise murale correctement mise à la terre. • "Suffisamment spacieux pour vous permettre d'accéder aux câbles d'alimentation (ceux-ci étant le seul moyen de mettre le système hors tension). Intel® Modular Server System MFSYS25 User Guide...
  • Page 132: Español

    Para ello: 1. Desbloquee y extraiga el bloqueo de seguridad de la parte posterior del sistema, si se ha instalado uno. 2. Extraiga y guarde todos los tornillos de las tapas.Extraiga las tapas. Intel® Modular Server System MFSYS25 User Guide...
  • Page 133 • "Provisto de una toma de tierra correctamente instalada. • "Provisto de espacio suficiente como para acceder a los cables de alimentación, ya que éstos hacen de medio principal de desconexión del sistema. Intel® Modular Server System MFSYS25 User Guide...
  • Page 134: Italiano

    1. Aprire e rimuovere il lucchetto dal retro del sistema qualora ve ne fosse uno installato. 2. Togliere e mettere in un posto sicuro tutte le viti delle coperture. 3. Togliere le coperture. Intel® Modular Server System MFSYS25 User Guide...
  • Page 135 • "Dotata di una presa a muro correttamente installata. • "Dotata di spazio sufficiente ad accedere ai cavi di alimentazione, i quali rappresentano il mezzo principale di scollegamento del sistema. Intel® Modular Server System MFSYS25 User Guide...
  • Page 136 Intel® Modular Server System MFSYS25 User Guide...
  • Page 137: D Safety Information

    Indicates hot components or surfaces. Indicates do not touch fan blades, may result in injury. Indicates to unplug all AC power cord(s) to disconnect AC power Please recycle battery Intel® Modular Server System MFSYS25 User Guide...
  • Page 138: Intended Application Uses

    To remove power from system, you must unplug the AC power cord from the wall outlet. Your system may use more than one AC power cord. Make sure all AC power cords are Intel® Modular Server System MFSYS25 User Guide...
  • Page 139: System Access Warnings

    Turn off all peripheral devices connected to this product. • Turn off the system by pressing the power button to off. • Disconnect the AC power by unplugging all AC power cords from the system or wall outlet. Intel® Modular Server System MFSYS25 User Guide...
  • Page 140: Rack Mount Warnings

    Always handle boards carefully. They can be extremely sensitive to ESD. Hold boards only by their edges. After removing a board from its protective wrapper or from the server, place the board component side up on a grounded, static free surface. Use a Intel® Modular Server System MFSYS25 User Guide...
  • Page 141: Other Hazards

    Caution: To avoid risk of radiation exposure and/or personal injury: • Do not open the enclosure of any laser peripheral or device • Laser peripherals or devices have are not user serviceable • Return to manufacturer for servicing Intel® Modular Server System MFSYS25 User Guide...
  • Page 142: Deutsch

    Deutsch Sicherheitshinweise für den Server Das vorliegende Dokument bezieht sich auf Intel® Serverplatinen, Intel® Servergehäuse (Standfuß und Rack) sowie installierte Peripheriegeräte. Es enthält Warnungen und Vorsichtsmaßnahmen zur Vermeidung von Gefahren durch Verletzung, Stromschlag, Feuer und Beschädigungen von Geräten. Lesen Sie diese Dokument daher sorgfältig, bevor Sie Ihr Intel®...
  • Page 143: Zielbenutzer Der Anwendung

    Verwenden Sie mechanische oder andere geeignete Hilfsmittel zum Transportieren oder Anheben von Geräten. • Entfernen Sie alle Komponenten, die sich leicht abnehmen lassen, um das Gewicht zu reduzieren und die Handhabung zu erleichtern. Intel® Modular Server System MFSYS25 User Guide...
  • Page 144 Typ entspricht. Jedes Netzteil im System muß über ein eigenes Netzkabel angeschlossen werden. Einige Netzteile von Intel Servern verwenden Nullleitersicherungen. Vorsicht ist geboten im Umgang mit Netzteilen, welche Nullleitersicherungen verwenden, um das Risiko eines elektrischen Schlages zu vermeiden Das Netzteil in diesem Produkt enthält keine Teile, die vom Benutzer gewartet werden...
  • Page 145: Warnhinweise Für Den Systemzugang

    Einbauen von Hot-Plug-Komponenten sorgfältig vor, um nicht mit heißen Komponenten in Berührung zu kommen. Vorsicht: Berühren Sie nicht die rotierenden Lüfterflügel, um Verletzungen zu vermeiden. Falls Ihr System mit eine Lüfterabdeckung besitzt, darf es nicht ohne diese Abdeckung betrieben werden. Intel® Modular Server System MFSYS25 User Guide...
  • Page 146: Elektrostatische Entladungen (Esd)

    Ausbau aus dem Server mit der Bauelementseite nach oben auf eine geerdete, statisch entladene Unterlage.Verwenden Sie dazu, sofern verfügbar, eine leitfahige Schaumstoffunterlage, aber niche die Schutzhülle der Platine. Ziehen Sie die Platine nicht über eine Fläche. Intel® Modular Server System MFSYS25 User Guide...
  • Page 147: Andere Gefahren

    • Öffnen Sie keinesfalls das Gehäuse von Laser-Peripheriegeräten oder Laser- Komponenten. • Laser-Peripheriegeräte oder -Komponenten besitzen keine für den Benutzer wartungsbedürftigen Teile. • Schicken Sie das Gerät für Wartungsarbeiten an den Hersteller zurück. Intel® Modular Server System MFSYS25 User Guide...
  • Page 148: Français

    Français Consignes de sécurité sur le serveur Ce document s’applique aux cartes serveur Intel®, au châssis de serveur Intel® (sur pieds et sur rack) et aux périphériques installés. Pour réduire les risques de dommages corporels, d’électrocution, d’incendie et de dommages matériels, lisez ce document et respectez tous les avertissements et précautions mentionnés dans ce guide avant...
  • Page 149: Domaines D'utilisation Prévus

    • Utilisez l’assistance mécanique ou toute autre assistance appropriée lorsque vous déplacez et soulevez le matériel. • Pour réduire le poids en vue de faciliter la manipulation, retirez tout composant amovible. Intel® Modular Server System MFSYS25 User Guide...
  • Page 150 Vous devez les débrancher avant d’ouvrir le châssis, d’ajouter ou de supprimer un composant non connectable à chaud. Les alimentations de certains serveurs Intel sont munies de doubles fusibles pôle/neutre: veuillez observer les précautions d'usage afin d'éviter tout risque d'eléctrocution.
  • Page 151 Attention: Pour éviter de vous blesser, ne touchez pas les pales de ventilateur en mouvement. Si votre système est fourni avec une protection sur le ventilateur, ne mettez pas le système en route sans la protection en place. Intel® Modular Server System MFSYS25 User Guide...
  • Page 152: Décharges Électrostatiques (Esd)

    Utilisez si possible un tapi de mousse conducteru, mais pas l’emballage de la carte. Veillez à ce que la carte ne glisse sur aucune surface. Intel® Modular Server System MFSYS25 User Guide...
  • Page 153: Autres Risques

    Attention: Pour éviter tout risque d’exposition aux rayonnements et/ou de dommage personnel: • N’ouvrez pas l’enceinte d’un périphérique laser. • Les périphériques laser ne sont pas réparables par l’utilisateur. • Retournez-les au fabricant en cas de problème. Intel® Modular Server System MFSYS25 User Guide...
  • Page 154: Español

    Español Información de seguridad del servidor ® Este documento se aplica a las tarjetas de servidor de Intel , los gabinetes de servidor de ® Intel (montaje en rack y en pedestal) y los dispositivos periféricos. Para reducir el riesgo de daños corporales, descargas eléctricas, fuego y en el equipo, lea este documento y...
  • Page 155: Aplicaciones Y Usos Previstos

    Utilice medios mecánicos u otros que sean adecuados al trasladar o levantar el equipo. • Para que el peso sea menor para manipularlo con más facilidad, extraiga los componentes que sean de fácil extracción. Intel® Modular Server System MFSYS25 User Guide...
  • Page 156 CA estén desenchufado antes de abrir le gabinete, agregar o extraer cualquier componente que no es de conexión en funcionamiento. Algunas fuentes de alimentación de electricidad de los servidores de Intel utilizan el polo neutral del fuselaje. Para evitar riesgos de choques eléctricos use precauciones al trabajar con las fuentes de alimentación que utilizan el polo neutral de fuselaje.
  • Page 157: Advertencias El Acceso Al Sistema

    Precaución: Para evitar posibles daños, no toque las aspas en movimiento de los ventiladores. Si el sistema se le ha suministrado con una protección para el ventilador, asegúrese de que cuando esté funcionando el sistema la protección esté en su sitio. Intel® Modular Server System MFSYS25 User Guide...
  • Page 158: Descarga Electrostática (Esd)

    Utilice una almohadilla de espuma conductora si dispone de ella, pero nunca el envoltorio de la tarjeta. No deslice la tarjeta sobre ninguna superficie. Intel® Modular Server System MFSYS25 User Guide...
  • Page 159 Precaución: Para evitar el riesgo de la exposición a radiaciones o de daños personales: • No abra la caja de ningún periférico o dispositivo láser • Los periféricos o dispositivos láser no pueden ser reparados por el usuario • Haga que el fabricante los repare. Intel® Modular Server System MFSYS25 User Guide...
  • Page 160 表示如果无视此 “ ? ? ? 项 ” ? ? ? ? ? ? ? 轻微人身伤害或财产损失的危险。 警告 表示如果无视此 “ ? ? ” ? ? ? ? ? ? ? 严重人身伤害的危险。 表示如果无视所示信息,即存在潜在的危险。 表示如果不遵守安全指导,存在可导致严重伤害或死亡的电击危险。 表示灼热组件或表面。 表示请勿触摸风机叶片,否则可能致伤。 表示拔下所有交流电线,断开交流电源 Intel® Modular Server System MFSYS25 User Guide...
  • Page 161 • 远离振动源或物理震动。 • 与电气设备产生的强大电磁场隔离。 • 在易受闪电袭击的地区,我们建议将系统插入电涌抑制器并在闪电期间断开通信 线路与调制解调器之间的连接。 • 提供正确接地的墙壁插座。 • 提供足够的空间,以便拿取电源供应线,因为这是本产品的主要电源断开器。 设备操作规范 减少人身伤害或设备受损的危险: • 移举设备时遵守当地的职业健康与安全要求。 • 借助机械手段或其他合适的手段移举设备。 • 拆除一切易分离组件,以降低重量并方便操作。 电源与电气警告 注意事项 电源按钮(如待机电源标记所示)并不能完全关闭系统的交流电源,只要系统已接 通电源,就存在 5V 待机电源。要从系统切断电源,须从墙壁电源插座中拔下交流电线。您的系统可能 不止使用一根交流电线。请确保所有的交流电线都已拔下。打开机箱或增加或去除 任何热插拔组件之前,确保交流电线已拔下。 若非所需的确切类型,请勿尝试修改或使用交流电线。系统的每个电源供应设备都 需要一根单独的交流电线。 本产品的电源供应设备包含非用户维修部件。请勿打开电源供应设备。电源供应设 备包含非常危险的电压级、电流级和能量级。请与生产商联系维修事宜。 替换热插拔电源供应设备时,请先拔下需替换的电源供应设备上的电源线,再将其 从服务器上移除。 Intel® Modular Server System MFSYS25 User Guide...
  • Page 162 ⎯ 电源线须拥有适合插座的安全接地插头或触点。 • 电源线为交流电源的主要断开设备。插座须靠近设备并可随时断开。 • 电源线须插入所提供的拥有合适接地的插座。 系统使用警告 注意事项 为避免人身伤害或财产损失,无论何时检查产品内部,以下安全指导都适用: • 关闭所有与本产品相连的外设。 • 按下电源按钮至关闭状态,关闭系统。 • 从系统或墙壁插座上拔下所有交流电线,断开交流电源。 • 断开与系统相连的所有线缆和通信线路。 • 卸除舱口盖时,保留所有螺钉及其他紧固件。完成产品内部检查之后,请 用螺钉或紧固件重新固定舱口盖。 • 请勿打开电源供应设备。电源供应设备内没有可维修部件。请与生产商联系 维修事宜. • 增加或替换任何非热插拔组件之前,请关闭服务器电源并断开所有电源线 。 • 替换热插拔电源供应设备时,请先拔下需替换的电源供应设备上的电源线 ,然后再从服务器上移除电源供应设备。 注意事项 如果服务器一直在运行,任何已安装的处理器和吸热设备都可能很热。除非要增加 或移除热插拔组件,否则请待系统冷却后再开盖。为避免在热插拔组件安装过程中 接触灼热组件,移除或安装热插拔组件时务须小心。 Intel® Modular Server System MFSYS25 User Guide...
  • Page 163 注意事项 为避免受伤,请勿触摸运转的风机叶片。如果系统的风机上配有防护装置,请勿卸 下风机防护装置运行系统。 机架固定件警告 设备的机架须固定在稳固的支座上,以防从中安装服务器或设备时倒塌。须按照机 架生产商提供的安装说明进行安装。 从下往上将设备安装在机架上,最重的设备安装在机架的最底层。 一次只从机架上安装一件设备。 您须负责安装整个机架装置的主要电源断开设备。此主要断开设备须随时可用,且 须标明为控制整个装置(而不仅限于服务器)的电源。 为避免潜在的电击危险,须对机架及其上所安装的每一件设备实行正确的安全接地 。 静电放电 (ESD) 注意事项 ESD 会损坏磁盘驱动器、主板及其他部件。我们建议您执行 ESD 工作站的所有步骤。如果没有 ESD 工作站,则采取一些静电放电保护措施,操作部件时,戴上与服务器上的机箱接地 或任何未喷漆金属表面连接的防静电腕带。 操作主板时始终保持小心。它们可能对 ESD 非常敏感。拿持主板时只接触边缘。从保护包装中或从服务器上取出主板后,请将 主板组件侧面朝上放置在无静电的接地表面上。请使用导电泡沫垫(若有),不要 使用主板包装。请勿将主板在任何表面上滑动。 Intel® Modular Server System MFSYS25 User Guide...
  • Page 164 其他危险 替换电池 注意事项 不正确替换电池可能导致爆炸危险。替换电池时,请只使用设备生产商推荐使用的 电池。 请按当地法规处置电池。 请勿对电池充电。 请勿拆卸、刺穿或以其他方式损坏电池。 冷却和气流 注意事项 按照说明小心布置线缆,尽量减少气流阻塞和冷却问题。 为保证适当的冷却和气流,运行系统时请确保机箱盖已安装。未安装机箱盖即运行 系统可能导致系统部件受损。安装机箱盖的步骤如下: 首先检查并确保系统内没有遗留的未固定工具或部件。 • 检查线缆、内插板和其他组件已正确安装。 • 按产品说明安装机箱盖。 • 激光外设或激光设备 注意事项 为避免幅射暴露和 / 或人身伤害: 请勿打开任何激光外设或激光设备的外壳 • 激光外设或激光设备为非用户维修设备 • 请与生产商联系维修事宜 Intel® Modular Server System MFSYS25 User Guide...