Intel® Server System M50FCP2UR System Integration and Service Guide
6.11 M.2 Storage Device Replacement
The server board includes two M.2 connectors as shown in the following figure. Each M.2 connector supports
a PCIe* NVMe or SATA SSD drive that conforms to a 22110 (110 mm) or 2280 (80 mm) form factor.
Required Tools and Supplies
Replacement M.2 SSD
•
•
Anti-static wrist strap and conductive workbench pad (recommended)
Phillips* head screwdriver #1
•
1. Power off the system and disconnect the system power cords.
2. Remove the system top cover (see
3. Remove the air duct (see
4. Remove the Riser #1 assembly (see
5. Locate the M.2 to be replaced.
6. Remove the screw to release the M.2 SSD from the server board (see Letter A).
7. Carefully lift the free end of the M.2 SSD and gently remove it from the connector in the direction
shown (see Letter B).
8. Locate and carefully unpack the replacement M.2 SSD. Hold it by its edges.
104
Figure 145. M.2 SSD Removal
Section
6.1.1).
Section
6.2.1)
Section
6.7).
Figure 146. M.2 SSD Installation