Figure 144. Ocp* Adapter With Internal Lock Installation - Intel M50FCP2UR Integration And Service Manual

Table of Contents

Advertisement

Intel® Server System M50FCP2UR System Integration and Service Guide
2. Remove the air duct (see
Section
6.2.1)
3. Remove the Riser #2 assembly above the OCP adapter area (see
Section
6.7)
4. Squeeze the two hooks of the internal lock and remove it from the OCP rail (see Letter A).
5. Turn the lock over and reinstall it back onto the OCP rail (see Letter B).
6. Push the OCP card out of the bay from inside the chassis (see Letter C).
7. Locate and unpack the replacement OCP card

Figure 144. OCP* Adapter with Internal Lock Installation

8. Squeeze the two hooks of the internal lock and remove it from the OCP rail (see Letter A).
9. Align the OCP adapter with the open OCP bay slot and push forward until the connectors make
secure contact (see Letter B).
10. Reinstall the internal lock with the lock orientation (see Letter C).
11. Reinstall the riser card assembly as needed (see
Section
6.7).
12. Reinstall the air duct (see
Section
6.2.2).
13. Reinstall the system top cover (see
Section
6.1.2).
103