Pc Drum Charging Section; Pc Drum Charge Corona On/Off Control - Minolta CF910 Service Manual

Hide thumbs Also See for CF910:
Table of Contents

Advertisement

1154SBM0800A
8

PC DRUM CHARGING SECTION

• The PC Drum Charge Corona has a Scorotron grid to deposit a negative DC charge
evenly across the surface of the PC Drum.
• The grid voltage (VG) applied to the grid mesh is kept in the range between –400 and
–1100V by the Constant-Voltage Circuit in High Voltage Unit 1 HV1. The constant volt-
age of HV1 is determined through image stabilization control.
1154SBM0801A
8-1.

PC Drum Charge Corona ON/OFF Control

High Voltage Unit 1
HV1 (PC Drum
Charge Corona)
Transfer Drum
Reference Position
Sensor PC20
Start Key ON
ON
PC Drum Drive
OFF
Motor (M18)
ON
HV1
OFF
H
PC20
L
Grid Mesh
PC Drum
Control Signal
PWB-I PJ11I-9
Control Signal
PWB-I PJ4I-5B
M-19
Corona Wire
HV1
Constant-Voltage
Circuit
1144M026AA
Energized
Deenergized
L
H
Blocked
Unblocked
L
H
End of Copy Cycle
Wiring Diagram
15-I
Wiring Diagram
15-E
1144M10TCC

Advertisement

Table of Contents
loading

Table of Contents