1. CF910 to CF911P Changes List

1-1. The CF911P does not contain the following CF910 parts (Electrical Parts List).
LA1
Exposure Lamp
M1
Scanner Motor
M2
Original Glass Cooling Fan Motor
M24
IR Cooling Fan Motor 1
M25
IR Cooling Fan Motor 2
PC1
Scanner Home Position Sensor
PC2
Original Cover Angle Detection Sensor
PU2
DC Power Supply 2
PWB-A
CCD Sensor Board
PWB-B
A/D Converter Board
PWB-G
Motor Drive Board
PWB-
Tech. Rep. Setting Switches Board
SE1
Original Size Detecting Sensor 1 (OP)
SE2
Original Size Detecting Sensor 2
SE3
Original Size Detecting Sensor 3
SE4
Original Size Detecting Sensor 4 (OP)
1-2. The following part has been changed.
UN27
From CF910 Control Panel to CF911P Operation Panel.
1-3. The CF911P includes the new parts listed below.
FIERY X2E
PWB-E
1-4. General manual changes.
1. Change the Touch Panel to the Control Panel and/or PC screen.
2. Change the Malfunction Reset switch to the Trouble Reset key on the panel that
appears in "Clear Mode" on the PC screen.
3. Image stabilization problem indicator is not applicable.
4. Security Mode is not applicable.
5. Additional Notes:
When the power is switched on but the CF911P does not display "Ready," switch
the power Off and On again.
When the Message "Alert, Service Code" is displayed, press the down key, display
the Error Code on the second line.
Printer Controller Board
Controller Interface Board
-2-