7. C0060 (M17's Failure to Turn)
C0061 (M17 Turning at Abnormal Timing)
• Fusing Motor M17
Step
1
Is the malfunction code C0060 shown?
2
Does M17 turn when the Start key is
pressed?
3
Does the voltage across PJ6I-4 on PWB-I
and GND change from DC5V to DC0V
when the Start key is pressed?
4
Does the voltage across PJ6I-6 on PWB-I
and GND remain DC5V when the Start
key is pressed?
5
Does the voltage across PJ6I-4 on PWB-I
and GND remain DC0V when the Start
key is pressed?
6
Does the voltage across PJ6I-6 on PWB-I
and GND remain DC0V when the Start
key is pressed?
Possible Defective Components
Check Item
T-36
• Master Board PWB-I
1154C14TAA
Result
NO
Go to step 5.
YES Check rollers, gears, etc. for
overload.
NO
Change PWB-I.
YES Change M17.
NO
Change PWB-I.
NO
Change PWB-I.
YES Change M17.
NO
Change PWB-I.