(15) Replacement of the Backup Blade 1 and Backup Blade 2
2. Transfer Film
3. Backup Blade 2
Fig. 1
Replace.
Fig. 1 Screws to be removed to remove Backup Blades 1 and 2
Paper Attraction
Detection Sensor 2
Clean.
1. Synchronizing/Static Charge Roller Assy
Remove these three screws only.
D-94
Paper Attraction
Detection Sensor 1
Clean.
4. Backup Blade 1
Fig. 1
Replace.
1154D197AB