Adjustment Of The Amount Of Projection Of Backup Blade 2 And 1 - Minolta CF910 Service Manual

Hide thumbs Also See for CF910:
Table of Contents

Advertisement

(7) Adjustment of the Amount of Projection of Backup Blade 2 and 1

Scale
Adjusting Procedure
1. Remove the Transfer Film.
2. Loosen the adjusting screws.
3. Hold the scale at a right angle to the end face of the mounting bracket. Move the blade
bracket to obtain the specified length between the end face of the mounting bracket and
the blade tip, then tighten the adjusting screws.
Backup Blade 2 Projection Standard
Blade Bracket
Adjusting Screw
Adjusting Screw
(Backup Blade 1)
Adjusting Screw
(Backup Blade 2)
Mounting Bracket
19.5±0.3 mm
Blade
1144D265AA
D-144
Scale
Backup Blade 1 Projection Standard
Mounting Bracket
Blade Bracket
Adjusting Screw
Adjusting Screw
(Backup Blade 1)
Adjusting Screw
(Backup Blade 2)
1144D264YA
22.5±0.3 mm
Blade
1144D266AA

Advertisement

Table of Contents
loading

Table of Contents