Malfunction - Minolta CF910 Service Manual

Hide thumbs Also See for CF910:
Table of Contents

Advertisement

3

MALFUNCTION

• This copier has a CPU circuit that self-diagnoses the copier conditions. On detection of a
malfunction, it shows on the Touch Panel the corresponding code that consists of num-
bers and letters representing a particular malfunction name, location, and definition as
detailed below.
• Malfunctions can be reset by the following procedure.
Malfunction Resetting Procedure
• Open and close the Front Door. The Trouble Reset Switch must be pressed to reset the
malfunction of the Fusing and Exposure Lamp Sections.
• Disconnect and connect the option or open and close the option door for malfunctions of
options.
• Detailed data screen
• If a malfunction call indicator appears on the lower left corner of the Basic screen, it indi-
cates that something is wrong with the image stabilizer function. Touch that indicator to
open and check "Machine Status 2" (detailed data screen). (See the subsequent pages
for details of what malfunction each code shown on "Machine Status 2" represents.)
(See pp. T-80 and onward for troubleshooting procedures.)
Malfunction Resetting Procedure
• Open and close the Front Door.
C 0
<Image Stabilizer Malfunction>
1154T055AA
T-21
Malfunction definition code
Malfunction location code
Malfunction name code
1144T054CA
1154T048AA

Advertisement

Table of Contents
loading

Table of Contents