User Mode - Minolta CF910 Service Manual

Hide thumbs Also See for CF910:
Table of Contents

Advertisement

<Clearing Procedures>
• Memory Clear Test Point TP2
1. Turn ON the Power Switch and close the circuit across TP1 and TP2.
2. With the circuit across TP1 and 2 closed, turn OFF the Power Switch and, approx. 10
sec. later, turn ON the Power Switch again.
3. In approx. 5 sec., open the circuit across TP1 and 2.
NOTES
1. If an erratic operation or display occurs, perform the clearing procedures in the order of
S24 and TP2.
2. When memory clear has been performed, make the necessary settings again.
<List of Data Cleared by Switch and Point>
Clearing Method
Data Cleared
Misfeed display
Malfunction
display
Erratic operation/display

User mode

Following Service mode items
only:
• Fuser Oil Change
• Count Up Select
• Admin. Mode (access no.)
• RD-Mode
: Cleared –: Not cleared
The "Meter Count" counts are not cleared.
Front Door
Open/Close
Fusing/
Optical
Others
Trouble Reset
Switch S24
S-8
Memory Clear
Test Point TP2