4. Technical data

4.1 Reference condition and limitations

Table 5 Reference conditions
Parameter
Relative humidity
Air inlet temperature
Exhaust back pressure
Ambient barometric pressure
Table 6 Limitations
Parameter
Minimum ambient temperature
Maximum ambient temperature
Minimum permitted inlet temperature
Maximum permitted inlet temperature
Maximum (absolute) inlet pressure
Maximum vessel pressure
6996022910_B
6996022910_B - Technical data
Page 60
Unit
Value
%
°C
°F
mbar(g)
psig
mbar(a)
1013
psia
14.7
Unit
Value
°C
°F
32
°C
46
°F
115
°C
-10
°F
14
°C
70
°F
158
mbar(a)
1050
psia
15.2
mbar(a)
1500
psia
21.8