Start The Pump; During Operation - Edwards EOSi Series Instruction Manual

Oil-sealed rotary screw vacuum pumps
Table of Contents

Advertisement

13.
Make sure that no dirt enters the oil system.
14.
Give labels, warnings as follows:
15.
Check the programmed settings. Refer to
16.
Close the isolation valve.
17.
Start and operate the pump for a few minutes. Check that the pump operates
normally.
18.
Open the inlet isolation valve.

8.2 Start the pump

Refer to
To start the pump do the steps that follow:
1.
Set the electrical supply to on.
2.
Make sure that the voltage on LED illuminates.
3.
Push the start button on the control panel. The pump operates and the automatic
operation LED illuminates.
4.
Open the inlet isolation valve.

8.3 During operation

WARNING: OPERATION SAFETY
Risk of injury or damage to equipment. Do not operate the pump with the enclosure
panels removed.
Note:
When the automatic operation LED is on, the pump can start automatically.
When the automatic operation LED is on, the controller controls the pump, for example,
to load, stop and restart the motors.
Regularly check the oil level during the operation.
6996022910_B
6996022910_B - Operation
The pump can automatically restart after a voltage failure (if ARAVF is
activated, contact us).
The pump is automatically controlled and can be automatically restarted.
The pump can be remotely controlled.
Figure:
Controller.
Programmable settings
Page 97
on page 58.