Converter Fault Codes - Edwards EOSi Series Instruction Manual

Oil-sealed rotary screw vacuum pumps
Table of Contents

Advertisement

Cause
Pressure switch out of order
Remedy
Replace the pressure switch.
Fault
Pump element outlet temperature above normal
Cause
Oil level too low
Remedy
Check and fill the oil. Refer to
Cause
Cooling air or cooling air temperature is not sufficient or relative humidity is too
high
Remedy
Check for the cooling air restriction or increase the ventilation of the pump room.
Prevent the recirculation of the cooling air. If installed, check the capacity of the
pump room fan.
Cause
Oil cooler clogged
Remedy
Clean the cooler.
Cause
Oil filter clogged
Remedy
Replace the oil filter.
Cause
Scavenge line clogged
Remedy
Clean the scavenge line.
Cause
By-pass valve malfunctioning
Remedy
Test the valves.
Cause
Degraded oil
Remedy
Check the service intervals. Refer to
Cause
Temperature of the process air too high
Remedy
Check the process air temperature.
Cause
Pump element out of order
Remedy
Contact us.

10.2 Converter fault codes

If the converter detects the problem, a specific code (Main motor converter alarm) and
the fault code is shown on the controller display.
Refer to for the important error codes. If another code appears, contact us.
6996022910_B
6996022910_B - Fault finding
During operation
Preventive maintenance schedule
Page 113
on page 97.
09/2021 - ©Edwards Limited
on page 100.

Advertisement

Table of Contents
loading

Table of Contents