Drive Info - gefran SIEIDrive ADL300 Functions Description And Parameters List

Vector inverter for lifts with asynchronous motors
Hide thumbs Also See for SIEIDrive ADL300:
Table of Contents

Advertisement

2 - DRIVE INFO

This menu displays the information for identifying and configuring the drive.
Menu
PAR
Description
2.1
476
Drive type
The drive series identification code is displayed.
The drives reporting 24V in the description can be feeded by an external 24Vdc power supply. For schematics and connec-
tion diagrams please refer to Quick Start manual.
0
Basic-Sin
1
Advanced
2
Basic-VGA
3
Basic-End
128 Basic-Sin 24V
129 Advanced 24V
130 Basic-VGA 24V
131 Basic-End 24V
Menu
PAR
Description
2.2
480
Control type
The control mode is displayed.
11
Asynchronous
12
Synchronous
Menu
PAR
Description
2.3
482
Drive size
The drive size identification code is displayed.
Menu
PAR
Description
2.4
484
Drive family
The available mains voltage is displayed (e.g. 400V). The undervoltage alarm refers to this voltage value.
The condition No power occurs when the regulation board has just left from production and has never been configured for
any power. The configuration adjustment for a given power is achieved by linking it to a power board and running a Save
parameters.
0
No Power
1
230V..480V
2
500V..575V
3
690V
4
230V
Menu
PAR
Description
2.5
486
Drive region
Setting of the geographical area in which the drive is to be used (Europe or USA). This setting determines the factory volt-
age and power supply frequency values.
0
EU
1
USA
Menu
PAR
Description
2.6
488
Drive cont current
The current that the drive can deliver continuously according to size, supply voltage and programmed switching frequency
is displayed.
Menu
PAR
Description
2.7
490
Firmware ver.rel
The version number and release number of the drive firmware are displayed. On the keypad these are displayed in the ver-
sion.release format. The parameter reading from the serial communication device or fieldbus returns the version in the high
byte and the release in the low byte.
10
UM
Type
FB BIT
ENUM
UM
Type
FB BIT
ENUM
UM
Type
FB BIT
UINT16
UM
Type
FB BIT
ENUM
UM
Type
FB BIT
ENUM
(400V / 50Hz)
(460 / 60 Hz)
UM
Type
FB BIT
A
FLOAT
UM
Type
FB BIT
UINT16
ADL300 • Functions description and parameters list
Def
Min
Basic-Sin
1
Def
Min
Asynchronous
0
Def
Min
0
0
Def
Min
No Power
0
Def
Min
EU
0
Def
Min
CALCF
0.0
Def
Min
0
0
Max
Acc
Mod
0
R
FVS
Max
Acc
Mod
0
R
FVS
Max
Acc
Mod
0
RS
FVS
Max
Acc
Mod
0
RS
FVS
Max
Acc
Mod
1
R
FVS
Max
Acc
Mod
0.0
RZS
FVS
Max
Acc
Mod
0
R
FVS

Advertisement

Table of Contents
loading

Table of Contents