gefran SIEIDrive ADL300 Functions Description And Parameters List page 105

Vector inverter for lifts with asynchronous motors
Hide thumbs Also See for SIEIDrive ADL300:
Table of Contents

Advertisement

Menu
PAR
Description
22.18
4560 SpdFbkLoss activity
Drive behaviour in case of the Speed fbk loss alarm is displayed. This alarm indicates the loss of the encoder feedback
signals. Each type of encoder generates the Speed fbk loss alarm differently (incremental signal error, absolute signal er-
ror, serial error).
0
Ignore
1
Warning
2
Disable
3
Stop
4
Fast stop
For absolute Endat encoders and absolute Hiperface encoders, after the alarm is generated, the encoder reset command
must be sent to the encoder: during this procedure the application verifies whether the encoder is signalling an encoder
alarm condition to the drive and the alarm is acquired from this.
The causes of the Speed fbk loss alarm and the information acquired from the encoder are shown in the SpdFbkLoss
code parameter 2172.
Note!
See menu 15.13 for further information.
Menu
PAR
Description
22.19
4562 SpdFbkLoss holdoff
Setting of the delay between the signalling of the speed feedback loss alarm condition SpdFbkLoss and the enabling of
the alarm. If an alarm condition occurs, the drive will wait for the set time before enabling the alarm. If the alarm is removed
within the set time, the drive will not indicate any alarm condition.
Menu
PAR
Description
22.20
4564 SpdFbkLoss threshold
If using incremental digital encoders in single-ended mode, this parameter sets the limit above which the drive executes
the action set with parameter 4560 SpdFbkLoss activity.
Menu
PAR
Description
22.21
4570 Drive ovld activity
Setting of the behaviour of the drive in case of a drive overload alarm Drive ovld. This alarm indicates that the drive over-
load threshold has been reached.
0
Ignore
1
Warning
2
Disable
3
Stop
4
Fast stop
Menu
PAR
Description
22.22
4572 Motor ovld activity
Setting of the behaviour of the drive in case of a motor overload alarm Motor ovld. This alarm indicates that the motor
overload threshold has been reached.
0
Ignore
1
Warning
2
Disable
3
Stop
4
Fast stop
Menu
PAR
Description
22.23
4574 Bres ovld activity
Setting of the behaviour of the drive in case of a braking resistor overload alarm Bres ovld. This alarm indicates that the
braking resistor overload threshold has been reached.
0
Ignore
1
Warning
2
Disable
3
Stop
4
Fast stop
Menu
PAR
Description
22.24
4582 HTsens restart
UM
Type
FB BIT
ENUM
UM
Type
FB BIT
ms
UINT16
UM
Type
FB BIT
rpm
INT16
UM
Type
FB BIT
ENUM
UM
Type
FB BIT
ENUM
UM
Type
FB BIT
ENUM
UM
Type
FB BIT
ENUM
ADL300 • Functions description and parameters list
Def
Min
Disable
0
Def
Min
200
0
Def
Min
100
5
Def
Min
Disable
0
Def
Min
Warning
0
Def
Min
Disable
0
Def
Min
Disable
0
Max
Acc
Mod
4
RW
FVS
Max
Acc
Mod
10000
RW
FVS
Max
Acc
Mod
CALCI
RW
FV_
Max
Acc
Mod
4
ERW
FVS
Max
Acc
Mod
4
ERW
FVS
Max
Acc
Mod
4
ERW
FVS
Max
Acc
Mod
1
ERW
FVS
105

Advertisement

Table of Contents
loading

Table of Contents