gefran SIEIDrive ADL300 Functions Description And Parameters List page 104

Vector inverter for lifts with asynchronous motors
Hide thumbs Also See for SIEIDrive ADL300:
Table of Contents

Advertisement

4
Fast stop
Menu
PAR
Description
22.9
4524 MotorOT restart
Enabling of automatic restart after the motor overtemperature alarm MotorOT.
0
Disable
1
Enable
Menu
PAR
Description
22.10
4526 MotorOT restart time
Setting of the time within which the Motor Overtemperature alarm must be reset in order to perform automatic restart.
Menu
PAR
Description
22.11
4528 MotorOT holdoff
Setting of the delay between the signalling of the motor overtemperature alarm MotorOT and enabling of the alarm. If an
alarm condition occurs, the drive will wait for the set time before enabling the alarm. If the alarm is removed within the set
time, the drive will not indicate any alarm condition.
Menu
PAR
Description
22.12
4540 Overspeed threshold
Setting of the threshold above which the overspeed alarm Overspeed is enabled.
Menu
PAR
Description
22.13
4542 Overspeed activity
Setting of the behaviour of the drive in case of a motor overspeed alarm Overspeed. This alarm indicates that the motor
speed has exceeded the threshold set in the Speed ref top lim and Speed ref bottom lim parameters in the COM-
MANDS menu.
0
Ignore
1
Warning
2
Disable
3
Stop
4
Fast stop
Menu
PAR
Description
22.14
4544 Overspeed holdoff
Setting of the delay between the signalling of the motor overspeed alarm Overspeed and enabling of the alarm. If an alarm
condition occurs, the drive will wait for the set time before enabling the alarm. If the alarm is removed within the set time,
the drive will not indicate any alarm condition.
Menu
PAR
Description
22.15
4550 SpdRefLoss threshold
Setting of the threshold below which the speed reference loss alarm SpdRefLoss occurs .
Menu
PAR
Description
22.16
4552 SpdRefLoss activity
Setting of the behaviour of the drive in case of a speed reference loss alarm SpdRefLoss. This alarm indicates that the
difference between the speed regulator reference and the actual motor speed is more than 100 rpm.
0
Ignore
1
Warning
2
Disable
3
Stop
4
Fast stop
Menu
PAR
Description
22.17
4554 SpdRefLoss holdoff
The delay between the Speed ref loss alarm condition signal and activation of the actual alarm. If an alarm condition oc-
curs, the drive will wait for the set time before enabling the alarm. If the alarm is removed within the set time, the drive will
not indicate any alarm condition.
104
UM
Type
FB BIT
ENUM
UM
Type
FB BIT
ms
UINT16
UM
Type
FB BIT
ms
UINT16
UM
Type
FB BIT
rpm
INT16 INT32
UM
Type
FB BIT
ENUM
UM
Type
FB BIT
ms
UINT16
UM
Type
FB BIT
rpm
INT16
UM
Type
FB BIT
ENUM
UM
Type
FB BIT
ms
UINT16
ADL300 • Functions description and parameters list
Def
Min
Disable
0
Def
Min
1000
120
Def
Min
1000
0
Def
Min
CALCI
0
Def
Min
Disable
0
Def
Min
0
0
Def
Min
100
0
Def
Min
Warning
0
Def
Min
1000
0
Max
Acc
Mod
1
RW
FVS
Max
Acc
Mod
30000
RW
FVS
Max
Acc
Mod
30000
RW
FVS
Max
Acc
Mod
CALCI
RW
FVS
Max
Acc
Mod
4
RW
FVS
Max
Acc
Mod
5000
RW
FVS
Max
Acc
Mod
CALCI
RW
FVS
Max
Acc
Mod
4
RW
FVS
Max
Acc
Mod
10000