Case 4: S-shaped ramp from high to low speed, low speed zone and subsequent stop with "landing control"
Distance multispeed0 (PAR 11102) ≠ 0 (es.0.5m), Enable landing sel (PAR 11130) = Enabled, Slow speed (PAR
11120) = Multispeed 0.
Deceleration space (PAR 12032) is the distance covered during the slow down ramp from Calc space hi-speed (PAR
11142) (high speed) to Multispeed 0 plus Landing zone dist (PAR 11132).
The parameters that influence the calculation of this distance are: Calc space hi-speed (PAR 11142), [11022] Multispeed
0 (PAR 11020), Percent dec factor (PAR 11056), Dec ini jerk (PAR 11046), Deceleration (PAR 11048) and Dec end jerk
(PAR 11050)
Menu
PAR
Description
5.5.18
12034 Landing zone space
The landing zone space is displayed. If this parameter is set to a value other than zero, this variable has the same value
as the parameter, if Landing zone space = 0 this variable assumes the value of the distance necessary to decelerate from
the speed set in Slow speed to zero using the ramp values not multiplied by the Percent dec factor.
34
Speed
PAR 11142
Calc space speed
UM
Type
FB BIT
m
FLOAT
ADL300 • Functions description and parameters list
PAR 12032
Deceleration space = A+Landing zone dist
PAR 11132
Landing zone dist
Def
Min
0
Time
Max
Acc
Mod
R
FVS