gefran SIEIDrive ADL300 Functions Description And Parameters List page 17

Vector inverter for lifts with asynchronous motors
Hide thumbs Also See for SIEIDrive ADL300:
Table of Contents

Advertisement

Menu
PAR
Description
4.15
576
Display backlight
Enabling of the backlight on the drive display.
If set to 0 the display backlight will go off when the drive has been on for three minutes.
If set to 1 the backlight will stay on for as long as the drive is powered.
Menu
PAR
Description
4.16
578
Language select
Setting of the drive programming language.
0
English
1
Italian
2
French
3
German
4
Spanish
8
Turkish
Note!
The Load Default command (par. 580) does not modify this parameter.
Menu
PAR
Description
4.17
580
Load default
Transfers the standard factory settings to the drive memory ("Def" column in the parameters table).
Menu
PAR
Description
4.18
590
Save par to keypad
Transfers the parameters currently stored in the drive and saves them in the keypad memory (See ADL300 Quick Start
manual, chapter 8.3.13).
Menu
PAR
Description
4.19
592
Load par from keypad
Transfers the parameters from the keypad memory to the drive (See ADL300 Quick Start manual, chapter 8.3.13).
Menu
PAR
Description
4.20
594
Keypad memory select
Selection of the area of the keypad memory to which to transfer and save the parameters stored in the drive.
Menu
PAR
Description
4.21
596
Save to SD card
Transfers the drive parameters to the SD memory card (See chapter 8.3.14 of the Quick start-up guide).
Menu
PAR
Description
4.22
598
Load from SD card
Transfers the parameters from the SD memory card to the drive (See chapter 8.3.14 of the Quick start-up guide).
Menu
PAR
Description
4.23
6100 Load synch control
Select the synchronous motor control mode. The drive is reset and restarts in the new control mode.
To perform this operation via keypad, see chapters 8.2.9 and 8.2.15 of the ADL 300 Quick Start Guide.
Note!
Important: the default parameters including the LIFT application are reloaded.
This can only be done with the drive disabled.
UM
Type
FB BIT
BIT
UM
Type
FB BIT
ENUM
UM
Type
FB BIT
BIT
UM
Type
FB BIT
BIT
UM
Type
FB BIT
BIT
UM
Type
FB BIT
UINT16
UM
Type
FB BIT
BIT
UM
Type
FB BIT
BIT
UM
Type
FB BIT
BIT
ADL300 • Functions description and parameters list
Def
Min
0
0
Def
Min
English
0
Def
Min
0
0
Def
Min
0
0
Def
Min
0
0
Def
Min
1
1
Def
Min
0
0
Def
Min
0
0
Def
Min
0
0
Max
Acc
Mod
1
ERW
FVS
Max
Acc
Mod
4
RWZ
FVS
Max
Acc
Mod
1
RWZ
FVS
Max
Acc
Mod
1
RW
FVS
Max
Acc
Mod
1
RWZ
FVS
Max
Acc
Mod
5
ERW
FVS
Max
Acc
Mod
1
RW
FVS
Max
Acc
Mod
1
RWZ
FVS
Max
Acc
Mod
1
ERW
FVS
17

Advertisement

Table of Contents
loading

Table of Contents