Functions/Pads - gefran SIEIDrive ADL300 Functions Description And Parameters List

Vector inverter for lifts with asynchronous motors
Hide thumbs Also See for SIEIDrive ADL300:
Table of Contents

Advertisement

4
Inp1>Inp2
5
|Inp1|=|Inp2|
6
|Inp1|!=|Inp2|
7
|Inp1|<|Inp2|
8
|Inp1|>|Inp2|
If set to 0 the comparator is not enabled
If set to 1 the comparator output is enabled when the value of Dig compare input 1 is inside the window resulting from the
value of Dig compare input 2 ± the tolerance set via the Comparator Window.
If set to 2 the comparator output is enabled when the value of Dig compare input 1 is not inside the window resulting from
the value of Dig compare input 2 ± the tolerance set via the Comparator Window.
If set to 3 the comparator output is enabled when Compare input 1 is less than Compare input 2.
If set to 4 the comparator output is enabled when Compare input 1 is greater than Compare input 2.
If set to 5 the comparator output is enabled when the value of Dig compare input 1 is inside the window resulting from the
absolute value of Dig compare input 2 ± the tolerance set via the Comparator Window.
If set to 6 the comparator output is enabled when the absolute value of Dig compare input 1 is not inside the window
resulting from the absolute value of Dig compare input 2 ± the tolerance set via the Comparator Window.
If set to 7 the comparator output is enabled when the absolute value of Dig compare input 1 is less than the absolute
value of Dig compare input 2.
If set to 8 the comparator output is enabled when the absolute value of Digital compar inp1 is more than the absolute
value of Digital compar in2.
Menu
PAR
Description
20.7.6
3672 Compare window
Setting of the tolerance window for comparing the Compare input 1 and Compare input 2 signals.
Menu
PAR
Description
20.7.7
3674 Compare delay
Setting of the delay for signalling the result of the comparison.
Menu
PAR
Description
20.7.8
3676 Compare output
The status of the comparator output is displayed:
0
The result of the set comparison is negative
1
The result of the set comparison is positive

20.8 - FUNCTIONS/PADS

The general variables are used to exchange data between the various components of a Bus system. They are similar to the vari-
ables of a PLC. Pads can be used, for example, to send information from a fieldbus to an optional card. All Pads can be read and
written.
Menu
PAR
Description
20.8.1
3700 Lift enable
20.8.2
3702 Run cont mon
20.8.3
3704 Up cont mon
20.8.4
3706 Down cont mon
20.8.5
3708 Brake cont mon
20.8.6
3710 Lift dc brake
20.8.7
3712 Brake 2 mon
20.8.8
3714 Door open mon
20.8.9
3716 Lift start
20.8.10 3718 Pad 10
20.8.11 3720 Lift status word
20.8.12 3722 Pad 12
20.8.13 3724 Pad 13
20.8.14 3726 Ramp down limit
20.8.15 3728 PAD 15
90
UM
Type
FB BIT
perc
FLOAT
UM
Type
FB BIT
s
FLOAT
UM
Type
FB BIT
BIT
16BIT
UM
Type
FB BIT
INT32 32BIT
INT32 32BIT
INT32 32BIT
INT32 32BIT
INT32 32BIT
INT32 32BIT
INT32 32BIT
INT32 32BIT
INT32 32BIT
INT32 32BIT
INT32 32BIT
INT32 32BIT
INT32 32BIT
INT32 32BIT
INT32 32BIT
ADL300 • Functions description and parameters list
Def
Min
0.0
0.0
Def
Min
0.0
0.0
Def
Min
0
0
Def
Min
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Max
Acc
Mod
100.0
ERW
FVS
Max
Acc
Mod
30.0
ERW
FVS
Max
Acc
Mod
1
ER
FVS
Max
Acc
Mod
0
ERW
FVS
0
ERW
FVS
0
ERW
FVS
0
ERW
FVS
0
ERW
FVS
0
ERW
FVS
0
ERW
FVS
0
ERW
FVS
0
ERW
FVS
0
ERW
FVS
0
ERW
FVS
0
ERW
FVS
0
ERW
FVS
0
ERW
FVS
0
ERW
FVS

Advertisement

Table of Contents
loading

Table of Contents