gefran SIEIDrive ADL300 Functions Description And Parameters List page 62

Vector inverter for lifts with asynchronous motors
Hide thumbs Also See for SIEIDrive ADL300:
Table of Contents

Advertisement

Menu
PAR
Description
14.6
2010 Rated power
Rated power of the motor at the rated voltage and frequency. This value represents the mechanical power produced on the
motor shaft.
Menu
PAR
Description
14.7
2012 Rated power factor
Motor power factor, as indicated on the data plate (Cos φ). This parameter is not always present on the motor data plate: in
that case use the default value present in the drive.
Menu
PAR
Description
14.8
2020 Take parameters
Saves the set motor data in the drive. This command must be supplied last after entering the appropriate values of all the
parameters listed above. This means calculating the normalization factors (a) and estimated values for the motor param-
eters (b). The drive cannot be started until the Take parameters command has been set.
Menu
PAR
Description
14.9
2022 Autotune rotation
Performs self-tuning in rotation: the motor must be uncoupled from the load or the transmission must not represent more
than 5% of the load. This procedure allows the greatest degree of accuracy in measuring the motor parameters. To ex-
ecute the command you must first open the hardware enabling contact between terminals 9 and DICM.
Selt-tuning can now be performed. At the end of the self-tuning procedure, open the contact between terminals 9 and
DICM again and reset the parameters that were modified.
Menu
PAR
Description
14.10
2024 Autotune still
Performs self-tuning with the motor coupled to the transmission. The self-tuning procedure may cause limited rotation of
the motor shaft. To perform self-tuning, follow the procedure described for the previous parameter.
Menu
PAR
Description
14.11
2026 Autotune mode
Selection of the motor parameter self-tuning mode
0
Reduced
1
Extended
If set to 0 all the motor parameters are measured except those relating to the non-linear saturation curve. Use this mode to
obtain a faster self-tuning procedure.
If set to 1 all the motor parameters are measured. Use this mode to obtain maximum efficiency: this procedure may take a
few minutes.
Menu
PAR
Description
14.12
2028 Take status
Indication of the status of parameter saving.
0
Required
1
Done
The parameter displays the Required message when the motor parameters that have been entered need to be saved.
When they have been saved the parameter indicates Done.
Menu
PAR
Description
14.13
2030 Autotune status
Indication of the status of execution of motor parameter self-tuning.
0
Required
1
Done
The parameter displays the Required message when motor parameter self-tuning is required. When self-tuning is com-
plete the parameter indicates Done.
Menu
PAR
Description
14.14
2050 Measured Rs
Measured value of the rotor resistance.
62
UM
Type
FB BIT
kW
FLOAT
UM
Type
FB BIT
FLOAT
UM
Type
FB BIT
BIT
UM
Type
FB BIT
BIT
UM
Type
FB BIT
BIT
UM
Type
FB BIT
ENUM
UM
Type
FB BIT
ENUM
UM
Type
FB BIT
ENUM
UM
Type
FB BIT
ohm
FLOAT
ADL300 • Functions description and parameters list
Def
Min
SIZE
0.1
Def
Min
SIZE
0.6
Def
Min
0
0
Def
Min
0
0
Def
Min
0
0
Def
Min
Reduced
0
Def
Min
Required
0
Def
Min
Required
0
Def
Min
CALCF
0.001
Max
Acc
Mod
1500.0
RWZS FVS
Max
Acc
Mod
0.95
RWZS FVS
Max
Acc
Mod
1
RWZ
FVS
Max
Acc
Mod
1
RWZ
FVS
Max
Acc
Mod
1
RWZ
FVS
Max
Acc
Mod
1
ERWZ FVS
Max
Acc
Mod
0
R
FVS
Max
Acc
Mod
0
R
FVS
Max
Acc
Mod
200.0
ERWS FVS

Advertisement

Table of Contents
loading

Table of Contents