Analog Inputs - gefran SIEIDrive ADL300 Functions Description And Parameters List

Vector inverter for lifts with asynchronous motors
Hide thumbs Also See for SIEIDrive ADL300:
Table of Contents

Advertisement

12 - ANALOG INPUTS

Note !
These parameters are only available with cards provided with analog inputs.
Menu
PAR
Description
12.1
1600 Analog input 1X mon
12.13
1650 Analog input 2X mon
The value of the voltage on the output of the function block of the relative analog input is displayed.
Menu
PAR
Description
12.2
1602 Analog inp 1X type
12.14
1652 Analog inp 2X type
Selection of the type of input (voltage or current). Depending on the input signal, move the switches on the regulation card.
The factory parameter is inputs set for differential voltage signals (± 10V).
0
-10V..+10V
1
0.20mA , 0.10V
2
4..20mA
Select option 0 in order to connect a maximum voltage of ±12.5V (typically ±10V/5mA) to the analog input concerned. If the
signal is used as a reference, reverse the direction of rotation by inverting the voltage polarity.
Select option 1 to connect a max voltage of 12.5V (typically 10V/5mA) or a signal in current from 0 ... 20 mA to the analog
input concerned. The signal must be positive.
Select option 2 to connect a current signal of 4...20 mA to the analog input concerned. The signal must be positive.
Menu
PAR
Description
12.3
1604 Analog inp 1X scale
12.15
1654 Analog inp 2X scale
Setting of a multiplier factor to be applied to the relative analog input of the expansion card.
Example :
The speed reference of a drive is assigned with a max external voltage of 5V. With this value the drive must reach the
maximum speed allowed (set using Full scale speed).
As the Analog inp XX scale parameter the scale factor of 2 is entered (10V : 5V)
Menu
PAR
Description
12.4
1606 An inp 1Xoffset tune
12.16
1656 An inp 2Xoffset tune
Self-tuning command for the offset of the relative analog input of the expansion card. Automatic fine tuning of the input.
To perform self-tuning, set the input signal to its minimum value and execute the command. The conditions containing an
offset can be compensated. When this command is sent, An inp xX offset tune is automatically selected so that the avail-
able input signal corresponds to the zero value of the variable.
56
UM
Type
FB BIT
cnt
INT16 16/32BIT
cnt
INT16 16/32BIT
UM
Type
FB BIT
ENUM
ENUM
UM
Type
FB BIT
FLOAT
FLOAT
Speed
100%
2
50%
1
0
5V
UM
Type
FB BIT
BIT
BIT
ADL300 • Functions description and parameters list
Def
Min
0
0
0
0
Def
Min
-10V..+10V
0
-10V..+10V
0
Def
Min
1.0
-10.0
1.0
-10.0
1
Analog inp x scale = 1,0
Analog inp x scale = 2,0
2
10V
Def
Min
0
0
0
0
Max
Acc
Mod
0
ER
FVS
0
ER
FVS
Max
Acc
Mod
2
ERW
FVS
2
ERW
FVS
Max
Acc
Mod
10.0
ERW
FVS
10.0
ERW
FVS
Max
Acc
Mod
1
ERW
FVS
1
ERW
FVS

Advertisement