To select set 1 manually, set this parameter to "One".
Otherwise select the desired source.
4
Modify the parameters in set 1 as necessary.
5
Save the parameters.
You can change the set being used by changing the source selected in parameter 3302 Par set select src. This can only
be changed with the drive disabled.
When the double parameter set is active, the number of the set being used is shown next to the number of each parameter
on the keypad.
Modifying and saving parameters:
When the double parameter set is active, any parameters that need to be the same in the two sets must be modified in
each set separately.
Parameters are only saved in the set that is active at the time. To save both sets, you must first save one and then select
and save the other.
Note!
Any changes to the parameters regarding the "parameter sets", performed when enabled, will be lost at the next switching unless a Par set 0
to 1 copy command is sent.
To save data permanently (even when the drive is switched off), send the Save parameters command (DRIVE CONFIG menu).

20.6 - FUNCTIONS/SPEED CAPTURE

Note!
This menu is not displayed if the lift application is enabled

20.7 - FUNCTIONS/COMPARE

This function allows the comparison among two signals or values.
Menu
PAR
Description
20.7.1
3650 Dig compare input 1
Setting of the digital value of the first element of comparison.
Menu
PAR
Description
20.7.2
3652 Dig compare input 2
Setting of the digital value of the second element of comparison.
Menu
PAR
Description
20.7.3
3660 Compare input 1 src
Selection of the origin (source) of the signal to be used as the first term of comparison. The values that can be selected in
the compare function are listed in the "L_CMP" selection list.
Menu
PAR
Description
20.7.4
3662 Compare input 2 src
Selection of the origin (source) of the signal to be used as the second term of comparison. The values that can be selected
in the compare function are listed in the "L_CMP" selection list.
Menu
PAR
Description
20.7.5
3670 Compare function
Setting of the compare function between Compare input 2 and Compare input 1 to enable Cmp output.
0
None
1
Inp1=Inp2
2
Inp1!=Inp2
3
Inp1<Inp2
UM
Type
FB BIT
perc
FLOAT 32BIT
UM
Type
FB BIT
perc
FLOAT 32BIT
UM
Type
FB BIT
LINK
32BIT
UM
Type
FB BIT
LINK
32BIT
UM
Type
FB BIT
ENUM
ADL300 • Functions description and parameters list
Def
Min
0.0
-200.0
Def
Min
0.0
-200.0
Def
Min
3650
0
Def
Min
3652
0
Def
Min
Nessuna
0
Max
Acc
Mod
200.0
ERW
FVS
Max
Acc
Mod
200.0
ERW
FVS
Max
Acc
Mod
16384
ERW
FVS
Max
Acc
Mod
16384
ERW
FVS
Max
Acc
Mod
8
ERW
FVS
89

Advertisement

Table of Contents
loading

Table of Contents