22 - ALARM CONFIG

In the ALARM CONFIG menu the type of effect any alarm signals have on the drive is determined:
-
The alarm status is saved
-
How must the drive react to the alarm signal?
-
Auto restart
-
Alarm reset
For some alarms, behaviour can be configured separately for each signal, while for the others the Disable drive is executed. Indi-
vidual signals can also be sent to a programmable digital output.
Activity
Ignore
Warning
Disable Drive
Stop
Fast stop
An alarms with Activity = Ignore or Warning can be enabled at the same time.
If an alarm with Activity = Stop or Fast Stop is enabled and another alarm with an Activity other than Ignore or Warning is enabled,
the drive stops and is disabled.
Not all alarms allow the controlled stopping of the drive. The following table shows the possibility of setting the Activities for the
individual alarm signals.
Alarm
ExtFlt
Motor OT
Overspeed
SpdRefLoss
SpdFbkLoss
Drive ovld
Motor ovld
102
The alarm is not included in the list of alarms, it is not included in the alarm log, it is not
signalled on the digital outputs, no drive commands are modified.
The alarm is included in the list of alarms, it is included in the alarm log, it is signalled on
the digital outputs, the First alarm information is updated, the Alarm enabled information
is updated, no drive commands are modified.
The alarm is included in the list of alarms, it is included in the alarm log, it is signalled on
the digital outputs, the First alarm information is updated, the Alarm enabled information
is updated, a command is sent to stop and disable the motor, which stops due to inertia.
The alarm is included in the list of alarms, it is included in the alarm log, it is signalled
on the digital outputs, the First alarm information is updated, the Alarm enabled informa-
tion is updated, a Stop command is sent. When the zero speed is reached the drive is
disabled. If Ramp control mode is enabled, the drive moves to the zero speed with the
set ramp time; when the Speed delay 0 signal is activated the drive is disabled. If Speed
control mode is enabled, the drive moves to the zero speed with the maximum current
possible; when the Speed delay 0 signal is activated the drive is disabled. If Torque
control mode is enabled, the drive moves to the zero speed with the time set by the load;
when the Speed delay 0 signal is activated the drive is disabled.
The alarm is included in the list of alarms, it is included in the alarm log, it is signalled on
the digital outputs, the First alarm information is updated, the Alarm enabled information
is updated, a Fast Stop command is sent. When the zero speed is reached the drive is
disabled. If Ramp control mode is enabled, the drive moves to the zero speed with the
set fast stop ramp time (deceleration time 3); when the Speed delay 0 signal is activated
the drive is disabled. If Speed control mode is enabled, the drive moves to the zero
speed with the maximum current possible; when the Speed delay 0 signal is activated
the drive is disabled. If Torque control mode is enabled, the drive moves to the zero
speed with the set load time; when the Speed delay 0 signal is activated the drive is
disabled.
Ignore
Warning
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ADL300 • Functions description and parameters list
Disable drive
Stop
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
Fast stop
ü
ü
ü
ü
ü
ü
ü

Advertisement

Table of Contents
loading

Table of Contents