17 - REGULATOR PARAM

Menu
PAR
Description
17.1
2250 Current reg P gain
Setting of the proportional coefficient of the current regulator.
Menu
PAR
Description
17.2
2252 Current reg I time
Setting of the integral coefficient of the current regulator.
Menu
PAR
Description
17.3
2260 Flux reg P gain
Setting of the proportional coefficient of the flux regulator.
Menu
PAR
Description
17.4
2262 Flux reg I time
Setting of the integral coefficient of the flux regulator.
Menu
PAR
Description
17.5
2264 Flux reg P gain OL
Setting of the flux regulator proportional gain when the drive is used in open loop sensorless vector control mode. This
parameter is set automatically by the self-tuning procedure.
Menu
PAR
Description
17.6
2266 Flux reg I time OL
Setting of the flux regulator integral time when the drive is used in open loop sensorless vector control mode. This param-
eter is set automatically by the self-tuning procedure.
Menu
PAR
Description
17.7
2270 Voltage reg P gain
Setting of the proportional coefficient of the voltage regulator.
Menu
PAR
Description
17.8
2272 Voltage reg I time
Setting of the integral coefficient of the voltage regulator.
Menu
PAR
Description
17.9
2280 Dead time limit
Setting of the dead time voltage compensation value.
The dead time compensation function (Dead time compensation), compensates the distortion of output voltage caused
by the voltage drop on the IGBT devices and their switching characteristics.
Distortion of output voltage could cause irregular motor rotation.
Menu
PAR
Description
17.10
2282 Dead time slope
Setting of the dead time compensation slope value.
Menu
PAR
Description
17.11
2290 Voltage base
Setting of the basic voltage of the motor. This parameter is calculated automatically by the self-tuning procedure.
Menu
PAR
Description
17.12
2292 Voltage margin
UM
Type
FB BIT
V/A
FLOAT
UM
Type
FB BIT
ms
FLOAT
UM
Type
FB BIT
A/Wb FLOAT
UM
Type
FB BIT
ms
FLOAT
UM
Type
FB BIT
A/Wb FLOAT
UM
Type
FB BIT
ms
FLOAT
UM
Type
FB BIT
Wb/V FLOAT
UM
Type
FB BIT
s
FLOAT
UM
Type
FB BIT
V
FLOAT
UM
Type
FB BIT
V/A
FLOAT
UM
Type
FB BIT
V
FLOAT
UM
Type
FB BIT
perc
FLOAT
ADL300 • Functions description and parameters list
Def
Min
CALCF
0.0
Def
Min
CALCF
0.01
Def
Min
CALCF
0.0
Def
Min
CALCF
0.01
Def
Min
CALCF
0.0
Def
Min
CALCF
0.01
Def
Min
CALCF
0.0
Def
Min
CALCF
0.1
Def
Min
SIZE
0.0
Def
Min
SIZE
0.0
Def
Min
CALCF
50.0
Def
Min
5.0
0.0
Max
Acc
Mod
0.0
ERWS F_S
Max
Acc
Mod
10000.0
ERWS F_S
Max
Acc
Mod
0.0
ERWS F__
Max
Acc
Mod
10000.0
ERWS F__
Max
Acc
Mod
0.0
ERWS __S
Max
Acc
Mod
10000.0
ERWS __S
Max
Acc
Mod
0.0
ERWS F_S
Max
Acc
Mod
100.0
ERWS F_S
Max
Acc
Mod
50.0
ERWS FVS
Max
Acc
Mod
200.0
ERWS FVS
Max
Acc
Mod
690.0
ERWS F_S
Max
Acc
Mod
10.0
ERWS F_S
73