Torque Config - gefran SIEIDrive ADL300 Functions Description And Parameters List

Vector inverter for lifts with asynchronous motors
Hide thumbs Also See for SIEIDrive ADL300:
Table of Contents

Advertisement

18 - TORQUE CONFIG

Menu
PAR
Description
18.1
2350 Torque curr lim Pos
Setting of the active torque limit of the drive for the positive current direction (clockwise rotation and anti-clockwise braking).
Menu
PAR
Description
18.2
2352 Torque curr lim Neg
Setting of the active torque limit of the drive for the negative current direction (anti-clockwise rotation and clockwise braking).
Menu
PAR
Description
18.3
2354 Torque curr lim sel
Setting of the type of behaviour of the drive in the current limit condition.
0
Off
1
T clim +/-
2
T clim mot/gen
3
T limit src
If set to 0 no specific type of current limitation is set.
If set to 1 the active positive torque limit is Torque curr lim Pos and the active negative torque limit is Torque curr lim Neg.
torque
Torque curr lim Pos
Torque curr lim Neg
Torque limits with Torque curr lim Sel = 1
If set to 2 three conditions are possible:
1 – If the motor speed is > +1% of Rated speed the active positive torque limit is Torque curr lim Pos and the active
negative torque limit is Torque curr lim Neg.
2 – If the motor speed is < -1% of Rated speed the active positive torque limit is Torque curr lim Pos and the active
negative torque limit is Torque curr lim Neg.
3 – If -1% of Motor non speed < motor speed < + 1% of Rated speed the active positive torque limit is Torque curr lim
Pos and the active negative torque limit is Torque curr lim Neg
If set to 3 the torque limits are symmetrical. The value written in the source selected via the Torque limit src parameter
(PAR 2358) is taken as the torque limit.This mode is not managed with SSC control mode.
Menu
PAR
Description
18.4
2358 Torque limit src
Selection of the origin (source) of the signal to be used for the torque current limit. The signals that can be associated with
the function are listed in the "L_LIM" selection list.
Menu
PAR
Description
18.5
2360 Torque climPos Inuse
The positive torque limit value currently being used is displayed.
78
UM
Type
FB BIT
A
FLOAT 16/32BIT
UM
Type
FB BIT
A
FLOAT 16/32BIT
UM
Type
FB BIT
ENUM
Torque curr lim Pos
speed
Torque curr lim Neg
UM
Type
FB BIT
LINK
16/32BIT
UM
Type
FB BIT
A
FLOAT 16/32BIT
ADL300 • Functions description and parameters list
Def
Min
CALCF
0.0
Def
Min
CALCF
0.0
Def
Min
Sorg limcoppia 0
torque
Torque curr lim Neg
Torque curr lim Pos
-1% of Rated speed
Torque limits with Torque curr lim sel = 2
Def
Min
3726
0
Def
Min
0.0
0.0
Max
Acc
Mod
CALCF
ERWS FVS
Max
Acc
Mod
CALCF
ERWS FVS
Max
Acc
Mod
3
ERWZ FVS
Torque curr lim Pos
speed
Torque curr lim Neg
+1% di Rated speed
Max
Acc
Mod
16384
ERWZ F_S
Max
Acc
Mod
0.0
ER
FVS

Advertisement

Table of Contents
loading

Table of Contents