14.27
680
Full scale speed
Setting of the reference value for all speed percentage data (References, Speed adaptives ...) corresponding to 100 % of
the actual speed. This parameter can only be changed with the inverter blocked (Enable drive = Disabled). The recom-
mended setting for the value of this parameter is the motor rated speed. If altered, the self-tuning procedure should be
repeated.
Full scale speed does not define the maximum possible speed. In any case, the maximum speed percentage value is ±
200 % of the Full scale speed value.
64
UM
Type
FB BIT
rpm
INT16
ADL300 • Functions description and parameters list
Def
Min
CALCI
50
Max
Acc
Mod
32000
RWZ
FVS